5.7.5 Reset Button

The RST button on the front panel has three functions on ICR-3200 routers:
Reboot the router:
Hold the RST button for less than 4 seconds, the router will be restarted.
Factory reset – restore the default configuration:
Hold the RST button for more than 4 seconds. The PWR LED turns off and on
again. We recommend holding down the RST button for 1 second after turning on the
PWR LED on the front panel.
Factory reset – restore the default configuration when unable to boot:
If the router is unable to boot due to a bad configuration, turn off the router (power
supply). Push and hold the RST button, turn on the router and hold the RST button for
at least 10 seconds. This will return the router to default configuration.
Before performing the factory reset of the router, it is recommended to back up the router
configuration settings (see Configuration manual for ICR-3200 routers) because reset of
the router will return all configuration settings to their default states.
In order to press the RST button it is necessary to use a narrow screwdriver or any other small
tool.
LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: info@lucom.de — www.lucom.de
Figure 18: Router reset