Serial Interfaces And I/O Port; Serial + I/O Connector; Connection Of Rs485; Connection Of I/O - Advantech ICR-3241 User Manual

Lte industrial
Hide thumbs Also See for ICR-3241:
Table of Contents

Advertisement

5.8.2 Serial Interfaces and I/O Port

The RS232 and RS485 serial interfaces together with the I/O interface are physically con-
nected to the 10-pin panel socket. All three interfaces are not isolated from the router. The
pinout of this conector is described in the tables below.
The I/O user interface is designed for binary input processing and binary output control.
By default, the binary output is open, so it is not grounded. The maximum binary output load
is 36 V at 500 mA. The constant current supplied by the binary input is 3 mA.
LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: info@lucom.de — www.lucom.de
Figure 21: Serial + I/O connector
Pin
Signal mark
1
B (+)
2
A (-)
3
GND
Table 10: Connection of RS485
Pin
Signal mark
4
BIN
5
BOUT
Table 11: Connection of I/O
Pin
Signal mark
6
RXD
7
CTS
8
GND
9
RTS
10
TXD
Table 12: Connection of RS232
22
Description
IN/OUT
IN/OUT
GROUND
Description
BINARY IN
BINARY OUT
Description
IN
IN
GROUND
OUT
OUT
ICR-3241

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icr-3241wIcr-3241-1ndIcr-3241w-1nd

Table of Contents