Function List
Code
A085
Operation mode selection
A086
Energy saving mode tuning
A092
Acceleration (2) time setting
A292
Acceleration (2) time setting, 2nd motor
A093
Deceleration (2) time setting
A293
Deceleration (2) time setting, 2nd motor
A094
Select method to switch to Acc2 / Dec2 profile
A294
Select method to switch to Acc2 / Dec2 profile, 2nd motor
A095
Acc1 to Acc2 frequency transition point
A295
Acc1 to Acc2 frequency transition point, 2nd motor
A096
Dec1 to Dec2 frequency transition point
A296
Dec1 to Dec2 frequency transition point, 2nd motor
A097
Acceleration curve selection
A098
Deceleration curve selection
A101
[OI]-[L] input active range start frequency
A102
[OI]-[L] input active range end frequency
A103
[OI]-[L] input active range start current
A104
[OI]-[L] input active range end voltage
A105
[OI]-[L] input start frequency enable
A131
Acceleration curve constant setting (for S, U, Inverse U)
A132
Deceleration curve constant setting (for S, U, Inverse U)
A141
A input select for calculate function
A142
B input select for calculate function
A143
Calculation symbol
A145
ADD frequency
A146
ADD direction select
A150
Curvature of EL-S-curve at the start of acceleration
A151
Curvature of EL-S-curve at the end of acceleration
A152
Curvature of EL-S-curve at the start of deceleration
A153
Curvature of EL-S-curve at the end of deceleration
A154
Deceleration stop frequency setting
A155
Deceleration stop time setting
A156
PID sleep function action threshold
A157
PID sleep function action delay time
A161
[VR] input active range start frequency
A162
[VR] input active range end frequency
A163
[VR] input active range start current
A164
[VR] input active range end voltage
A165
[VR] input start frequency enable
b001
Selection of automatic restart mode
b002
Allowable under-voltage power failure time
b003
Retry wait time before motor restart
b004
Instantaneous power failure / under-voltage trip alarm enable 00 (disabled) / 01 (enabled) / 02 (disabled during stopping and decelerating to stop)
Number of restarts on power failure /
b005
under-voltage trip events
b007
Restart frequency threshold
b008
Selection of retry after tripping
b010
Selection of retry count after undervoltage
b011
Start freq. to be used in case of freq. matching restart
b012
Level of electronic thermal setting
b212
Level of electronic thermal setting, 2nd motor
b013
Electronic thermal characteristic
b213
Electronic thermal characteristic, 2nd motor
b015
Free setting, electronic thermal frequency (1)
b016
Free setting, electronic thermal current (1)
b017
Free setting, electronic thermal frequency (2)
b018
Free setting, electronic thermal current (2)
b019
Free setting, electronic thermal frequency (3)
b020
Free setting, electronic thermal current (3)
 14
Function Name
00 (normal operation), / 01 (energy-saving operation)
0.0 to 100.0 [%]
0.01 to 99.99 / 100.0 to 999.9 / 1000. to 3600. [s]
0.01 to 99.99 / 100.0 to 999.9 / 1000. to 3600. [s]
0.01 to 99.99 / 100.0 to 999.9 / 1000. to 3600. [s]
0.01 to 99.99 / 100.0 to 999.9 / 1000. to 3600. [s]
00 (switching by 2CH terminal) / 01 (switching by setting) /
02 (Forward and reverse)
0.00 to 99.99 / 100.0 to 400.0 [Hz]
0.00 to 99.99 / 100.0 to 400.0 [Hz]
0.00 to 99.99 / 100.0 to 400.0 [Hz]
0.00 to 99.99 / 100.0 to 400.0 [Hz]
00 (linear) / 01 (S curve) / 02 (U curve) / 03 (inverted-U curve) / 04 (EL-S curve)
0.00 to 99.99 / 100.0 to 400.0 [Hz]
0.00 to 99.99 / 100.0 to 400.0 [Hz]
0 to 100 [%]
0 to 100 [%]
00 (A101) / 01 (0Hz)
01 to 10
01 to 10
00 (digital operator) / 01 (keypad potentiometer) / 02 (input via O) / 03 (input via OI) /
04 (external communication) / 05 (option) / 07 (pulse train frequency input)
00 (A141 + A142) / 01 (A141 - A142) / 02 (A141 × A142)
0.00 to 99.99 / 100.0 to 400.0 [Hz]
00 (frequency command + A145) / 01 (frequency command - A145)
0 to 50 [%]
0 to 50 [%]
0 to 50 [%]
0 to 50 [%]
0.00 to 99.99 / 100.0 to 400.0 [Hz]
0.0 to 60.0 [s]
0.00 to 99.99 / 100.0 to 400.0 [Hz]
0.0 to 25.5 [s]
0.00 to 99.99 / 100.0 to 400.0 [Hz]
0.00 to 99.99 / 100.0 to 400.0 [Hz]
0 to 100 [%]
0 to 100 [%]
00 (A161) / 01 (0Hz)
00 (tripping) / 01 (starting with 0 Hz) / 02 (starting with matching frequency) /
03 (tripping after deceleration and stopping with matching frequency) /
04 (restarting with active matching frequency)
0.3 to 25.0 [s]
0.3 to 100.0 [s]
00 (16 times) / 01 (unlimited)
0.00 to 99.99 / 100.0 to 400.0 [Hz]
00 (tripping) / 01 (starting with 0 Hz) / 02 (starting with matching frequency) /
03 (tripping after deceleration and stopping with matching frequency) /
04 (restarting with active matching frequency)
1 to 3 [times]
0.3 to 100.0 [s]
Set a level between 20% and 100% for the rated inverter current [A]
Set a level between 20% and 100% for the rated inverter current [A]
00 (reduced-torque characteristic) / 01 (constant-torque characteristic) /
02 (free setting)
0 to "electronic thermal frequency (2)" [Hz]
Range is 0 to inverter rated current Amps [A]
"electronic thermal frequency (1)" to "electronic thermal frequency (3)" [Hz]
Range is 0 to inverter rated current Amps [A]
"electronic thermal frequency (2)" to 400 [Hz]
Range is 0 to inverter rated current Amps [A]
Setting Range
[ ○ = Allowed × = Not parmitted]
Setting During
Change During
Default
Operation
Operation
Setting
(allowed or not)
(allowed or not)
00
×
×
50.0
10.00
10.00
10.00
10.00
×
×
00
×
×
00
×
×
0.00
×
×
0.00
×
×
0.00
×
×
0.00
×
×
01
×
×
01
×
0.00
×
0.00
×
20
×
100
×
00
×
02
×
02
×
02
×
03
×
00
×
0.00
×
00
×
×
10
×
×
10
×
×
10
×
×
10
×
0.00
×
0.0
×
0.00
×
0.0
×
0.00
×
0.00
×
0
×
100
×
01
×
00
×
1.0
×
1.0
×
00
×
00
×
0.00
×
00
×
3
×
1.0
Rated current
×
of inverter
Rated current
×
of inverter
×
01
×
01
×
0
×
0.00
×
0
×
0.00
×
0
×
0.00