MICRO-SPEED FUNCTION

Micro-speed is designed to temporarily restrict the speed of the hoist to a lower speed and to prevent high speed operations until
the function is released. The micro-speed function can be configured two ways.
2-STEP MAINTAINED MODE – This mode will switch to a 2-Step maintained speed set. This is helpful where the micro-speeds need
to be specific. This mode can also be used to provide a single speed by setting the low and high micro speed values the same value.
To use this mode P106 must have a value of 0.
PERCENTAGE MODE – This mode will take the value from P106 as a percentage of the standard speed set. Setting P106 to a value of
50 will provide a 50% reduction in speed to the standard speed sets for the configured speed control method.
In the chart below the digital input 4 is configured from the factory for micro-speed.
Function
Digital Input 4 Mirco-Speed Activation
Input
Mirco-Speed Low-Speed
Mirco-Speed High-Speed
Micro-Speed Mode
LIMIT TO 1
ST
SPEED FUNCTION
For applications where it is required to limit the VFD to 1
function. This is typically used for travel limits or when approaching an upper / lower hook limit. The parameter chart below
references setting either digital input 6 or digital input 7.
Function
Input 6 Configuration
Digital Input 6 Function
Digital Input 6 Contact Status
Input 7 Configuration
Digital Input 7 Function
Digital Input 7 Contact Status
Parameters
C004
P100
P105
P106
speed frequency you can configure an available digital input for that
st
Parameter
P113
C006
C016
P114
C007
C017
Value
59:MI4
500 (5.00 Hz)
1000 (10.00 Hz)
Value = 0 ( 2-STEP MAINTAINED )
Value > 0 ( PERCENTAGE MODE )
Value
2
61
00 = N.O
01 = N.C
2
62
00 = N.O
01 = N.C
Page 10