Hitachi WJ200-007MF Manual page 2

Pursuing the ideal compact inverter
Table of Contents

Advertisement

Industry-leading Levels of Performance
High starting torque of 200% or greater achieved
1
by sensorless vector control
Integrated auto-tuning function for easy sensorless vector control
realizes high torque suitable for applications requiring it such as crane
hoists, lifts, elevators, etc.
Example of Torque Characteristics
(%)
200
100
Torque
0
0.5 1 3 6 10
-100
-200
Auto-tuning to perform sensorless vector control can now be easily done.
Speed regulation at low-speed is greatly improved.
2
– Fluctuation is 1/2* compared with the previous model. –
Speed regulation at low speed has been drastically improved to
enhance process stability and precision.
• Frequency commanded by the inverter: 0.5Hz.
• Motor: Hitachi's standard 3-phase 5.5kW 4-pole totally enclosed type motor.
-1
* WJ200: 5min
, Previous model: 13min
Model Name Indication
WJ200 – 001 L F
Series Name
Applied Motor Capacity
001: 0.1kW – 150: 15kW
Power Source
M: 1-phase 100V class
S: 1-phase 200V class
L: 3-phase 200V class
H: 3-phase 400V class
 2
(when sized for heavy duty)
Example of Hitachi's standard motor. (7.5kW 4-pole)
20
30
40
50
60Hz
Speed (min
-1
)
(Example of WJ200-055LF)
-1
with Digital Operator
3
Trip avoidance functions
.
Minimum time deceleration function, over-current suppress function
and DC bus AVR function are incorporated. The functions reduce
nuisance tripping. Improved torque limiting/current limiting function
enables a load limit to protect machine and equipment.
Minimum time deceleration Function
OFF
Motor Current
DC Voltage
Output Frequency
Deceleration Time:
2.3 sec. reduction of deceleration time
resistor is achieved when the function is active.
Over-current Suppress Function*
OFF
Motor Current
Output Frequency
*Turn off this function for lifting equipment.
Model Configuration
Model Name
1-phase 100V
class
WJ200-xxx
CT
001
002
004
0.4
007
0.75
015
022
030
037
040
055
075
110
150
(Example of WJ200-075LF)
ON
Motor Current
DC Voltage
Output Frequency
4.2 sec.
Deceleration Time:
without a braking
ON
Trip
1-phase 200V
3-phase 200V
3-phase 400V
class
class
V T
CT
V T
CT
0.2
0.1
0.2
0.1
0.4
0.2
0.4
0.2
0.55
0.4
0.75
0.4
1.1
0.75
1.1
0.75
2.2
1.5
2.2
1.5
3.0
2.2
3.0
2.2
5.5
3.7
7.5
5.5
11
7.5
15
11
18.5
15
1.9 sec.
Motor Current
Output Frequency
class
V T
CT
0.75
0.4
1.5
0.75
2.2
1.5
3.0
2.2
4.0
3.0
5.5
4.0
7.5
5.5
11
7.5
15
11
18.5
15

Hide quick links:

Advertisement

Table of Contents
loading