Owners & Installation Alterra F175B-1 Freestanding Wood Fire Model: F175B-1 PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult an authorised installer, service agency or the distributor.
Page 2
Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area.
DATA BADGE This is a copy of the label that accompanies each F200B-1 Freestanding NOTE: Regency units are constantly being improved. Check the label on Wood Fire. We have printed a copy of the contents here for your review. the unit and if there is a difference, the label on the unit is the correct one. Regency Alterra Freestanding Wood Fire...
INSTALLATION RESIDENTIAL 10) Do not use grates or andirons or other even reduced heat output. Too tall a chimney may prompt excessive draft which can re- methods for supporting fuel. Burn directly INSTALLATION sult in very short burn times and excessive on the base or bricks where supplied.
INSTALLATION SIDE PANEL INSTALLATION Install side panels with screws as shown in diagram. Diagram 1 - Side Panel Install FAN INSTALLATION A 2 speed fan is supplied and needs to be fitted to the rear of the unit with screws supplied. Internal Blower Wiring Diagram (240V) BLACK WHITE...
INSTALLATION MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS Universal Default (1) Special (2) 475mm 475mm 160mm 160mm 175mm 175mm 160mm 160mm 78mm 78mm 300mm 300mm 875mm 875mm 969mm 969mm * Wall clearance taken from rear shield (not fan). Floor Protection A combustible floor must be protected by non-combustible material (like tile, concrete board, or as defined by local codes) extending beneath the heater as follows;...
OPERATING INSTRUCTIONS AIR SLIDE CONTROL FIRST FIRE OPERATING INSTRUCTIONS Both the primary and air wash drafts are control- When your installation is completed and in- led by the control rod located on the right side spected you are ready for your first fire. With your unit now correctly installed and safety of the unit (when facing the unit).
MAINTENANCE CREOSOTE MAINTENANCE 9) During the first few days it may be more difficult to start the fire. As you dry out your firebrick and your masonry flue, your draft When wood is burned slowly, it produces It is very important to carefully maintain your will increase.
PARTS LIST STOVE ASSEMBLY Part # Description Part # Description 1391000 Firebox Assembly 1390003 Bottom Rear Plate 8010104 Secondary Air Tube 1396000 Fan Kit Assembly 1141500 SS Air Tube Assembly 1390004 Black Right Panel 1390001 Door Hinge 1390007 SS Right Panel 8010108 Brick Set 1395000...
Regency Fireplace Products and evaluated for manufacturer defect. The authorised selling dealer is responsible for all in-fi eld service work carried out on your Regency product. Regency Fireplace Products will not be liable for results or costs of workmanship from unauthorised service persons or dealers.
Page 16
Register your Regency warranty online ® www.regency-fire.com.au Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.