Regency Fireplace Products Classic F1150CSA Owners & Installation Manual

Regency Fireplace Products Classic F1150CSA Owners & Installation Manual

Freestanding woodstove
Table of Contents

Advertisement

Quick Links

Classic™
Owners &
Installation Manual
Freestanding Woodstove
French Manual Download: https://bit.ly/3kYUA7z
www.regency-fire.com
Manuel en Français : https://bit.ly/3kYUA7z
MODEL: F1150CSA
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
0219WS027S
920-826
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
09.25.24

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Classic F1150CSA and is the answer not in the manual?

Questions and answers

Summary of Contents for Regency Fireplace Products Classic F1150CSA

  • Page 1 Classic™ Owners & Installation Manual Freestanding Woodstove French Manual Download: https://bit.ly/3kYUA7z www.regency-fire.com Manuel en Français : https://bit.ly/3kYUA7z MODEL: F1150CSA Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. 0219WS027S 920-826 FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
  • Page 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. “This wood heater has a manufacturer set minimum low burn rate that must not be altered.
  • Page 3: Table Of Contents

    table of contents Glass Installation .............22 SAFETY DECAL Wood Door & Handle Assembly ........23 Safety Label for F1150CSA .........4 Fan Installation ............24 DIMENSIONS Stainless Steel Smoke Deflector Installation ....25 Brick Flue Baffle Removal/Installation .......26 Unit Dimensions ............5 Outside Air Dimensions ..........5 OPERATION INSTALLATION Seasoned Firewood ..........27...
  • Page 4: Safety Decal

    safety decal This is a copy of the label that accompanies each NOTE: Regency units are constantly being Regency Freestanding Woodstove (F1150CSA). improved. Check the label on the unit and if there is We have printed a copy of the contents here for a difference, the label on the unit is the correct one.
  • Page 5: Dimensions

    dimensions Unit Dimensions Unit with legs 20" 508mm " 441mm 24" " 6" (152 mm) 610mm 165mm " 540mm Unit with pedestal 4-9/16" (115mm) Outside Air Dimensions Rear with pedestal with bottom heat shield + legs Front 4-15/16" (126mm) Rear 4-9/16"...
  • Page 6: Installation

    installation 1. Please read this entire manual before you install Too tall a chimney may prompt excessive draft • Do not install the chimney directly at and use your new woodstove. Failure to follow which can result in very short burn times and the outlet of the appliance.
  • Page 7: Modular Installation Options

    installation Modular Installation Options - WARNING: ONLY USE SPECIFIED COMPONENTS. The following items are required when assembling your Regency Stove. F1150CSA unit - the Rear Heat Deflector is supplied with the stove, but if you choose not to use it you must use the Airmate instead Modular Part See the Minimum Clearance to Combustible Materials chart in the Installation section of this manual.
  • Page 8: Stove Assembly Prior To Installation

    installation Stove Assembly Prior to Airmate Assembly Rear Heat Deflector Installation for F1150CSA Assembly for F1150CSA The F1150CSA unit requires the pedestal (or heat The rear heat deflector is supplied with the stove shield and legs) to be attached to the base. The 1.
  • Page 9: Pedestal Assembly Installation

    installation Pedestal Assembly Installation Bottom Heat Shield and Legs Installation 1. For easier assembly, tip the stove on its back (onto a soft surface to prevent scratching) and The instructions below apply to the painted cast remove the front cover. leg.
  • Page 10: Minimum Clearance To Combustible Materials

    installation Minimum Clearance to Combustible Materials Please read the section below carefully as clearances depend on whether single wall or double wall pipe is installed on the stove. Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall. Clearances may only be reduced by means approved by the regulatory authority.
  • Page 11: Minimum Alcove Clearance And Clearance To Combustible Materials

    installation Minimum Alcove Clearance and Clearance to Combustible Materials The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level. Single wall pipe (C Vent) is not approved for alcoves. Note: Minimum alcove ceiling height - 83"...
  • Page 12: Floor Protection (Corner Installation)

    installation Floor Protection (Corner Installation) (Ember Protection Only Required) A combustible floor must be protected by non-combustible material (like tile, concrete board, or certified to UL-1618 or as defined by local codes) extending beneath the heater and a minimum of 8" (203mm) from each side and minimum 18" (457mm)** from the front face of the stove and minimum 8"...
  • Page 13: Step-By-Step Chimney And Connector Installation

    installation Step-by-Step This stove may be connected to a lined masonry 8. If you are using a horizontal connector, chimney or a listed factory built chimney suitable the chimney connector should be as high Chimney and for use with solid fuels and conforming to ULC629. as possible while still maintaining the 18"...
  • Page 14: Masonry Chimney

    installation Masonry Chimney Ensure that a masonry chimney meets the minimum standards of the National Fire Protection Association (NFPA) by having it inspected by a professional. Make sure there are no cracks, loose mortar or other signs of deterioration and blockage. Have the chimney cleaned before the stove is installed and operated.
  • Page 15: Combustible Wall Chimney Connector Pass-Throughs

    installation Combustible Wall Chimney Connector Pass-throughs Minimum chimney clearance to brick Method A: 12" (304.8 mm) Clearance to Combustible Wall Member: and combustibles 2 in. (50.8mm) Using a minimum thickness 3.5" (89 mm) brick and a 5/8" (15.9 mm) minimum wall thickness clay liner, construct a wall pass-through. The Minimum clearance clay liner must conform to ASTM C315 (Standard Specification for 12 in.
  • Page 16: Transportable Building Installation

    installation Transportable Building Installation In addition to standard installation instructions the For Canadian Installations: See Outside following requirements are mandatory for installation Air Kit - Part # 846-502. in a Transportable Building. There are further requirements when installing this unit into a Transportable Building in 1.
  • Page 17: Transportable Building Kit - For Canada

    installation F1150CSA Transportable Building Kit - for Canada Transportable Building Kit - For Canada Note: The optional ashdrawer cannot be used when using the Transportable Building Kit. Note: The optional ash drawer cannot be used when using the Mobile Home Kit. The Transportable Building kit contains: 5.
  • Page 18: Installing Outside Air From Pedestal Base

    installation F1150CSA Installing Outside Air Using Bottom Heat Installing Outside Air From Pedestal Base Shield/Legs If installing outside air from pedestal base, do not remove knock out from rear of pedestal. This must remain in place. Transportable Building Mobile Home Box Square Transition Box Transportable Building Box Mobile Home Box...
  • Page 19: Recommended Heights For Woodstove Flue

    installation TABLE 1 MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET (Measured from the top of the unit) # OF ELBOWS ELEVATION (FT) ABOVE SEA LEVEL 2 x 15 4 x 15 2 x 30 4 x 30 2 x 45 4 x 45 0-1000 12.0 13.0...
  • Page 20: Optional Outside Air Kit

    installation Optional Outside Air Kit The Outside Air Kit is an option for Freestanding Stoves. Outside air for combustion can be brought in either through the bottom of the pedestal or through the rear plate of the pedestal. For both bottom and rear outside air the Pedestal Cover Plate must be installed. Loosen the 4 screws on the rear of the pedestal and slide the cover plate over them.
  • Page 21: Brick Installation

    installation Brick Installation Firebrick is included to extend the life of your stove and radiate heat more evenly. Check to see that all firebricks are in their correct positions and have not become misaligned during shipping. Install all firebricks (if bricks were removed at install) per the diagram below and place in their correct positions. Do not use a grate.
  • Page 22: Removing Wooden Handle

    installation Removing Wooden Glass Installation Handle Your Regency stove is supplied with 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact, purchase your replacement from an authorized 1.
  • Page 23: Wood Door & Handle Assembly

    installation WOOD STOVES & INSERTS Wood Door & Handle Assembly WOOD DOOR & HANDLE ASSEMBLY Place the door onto the hinges and then place the door handle through the opening on the door, as shown in In preparation of installing the door handle, the nuts, Diagram 2.
  • Page 24: Fan Installation

    installation F1500 Fan Installation Fan assembly for use only with the room heater marked to indicate such use. FAN INSTALLATION FAN OPERATION (120V FAN) The fan is controlled by a rheostat which allows control of the heat 1. Remove the two screws from the top of the fan housing. output.
  • Page 25: Stainless Steel Smoke Deflector Installation

    installation Stainless Steel Smoke Deflector Installation The stainless smoke deflector is located in the upper front area of the firebox. The deflector is held in place with 2 bolts. Prior to the first fire, ensure deflector is seated properly and secured with 2 hand tightened bolts which are accessible from behind the smoke deflector. Smoke deflector Smoke deflector is installed through the door opening in location shown in Diagram...
  • Page 26: Brick Flue Baffle Removal/Installation

    installation Brick Flue Baffle 4. Install two smaller baffle pieces on either side. Removal/Installation Baffle side pieces The flue baffle system located in the upper area of the firebox is removable to make cleaning your chimney system easier. The brick baffle must be installed prior to your first fire.
  • Page 27: Seasoned Firewood

    operating instructions Seasoned Firewood Operating Air Operating Instructions Handle The F1150 is supplied with an air operating handle. Whether you burn wood in a fireplace, stove or insert, With your unit now correctly installed and safety The handle is used to adjust the air control for the good quality firewood is the key to convenience, ef- inspected by your local authority, you are now ficiency and safety.
  • Page 28: First Fire

    operating instructions Optimum Fueling & Operating 6. Once this has burned down, open the door, and 12. Green or wet wood is not recommended for Procedures rake the coals to create a uniform charcoal bed. your unit. If you must add wet or green fuel, Load 5 pieces of 17”...
  • Page 29: Fan Operation

    operating instructions Safety Guidelines Fan Operation Ash Drawer Operating and Warnings Guidelines Automatic To operate the fan - turn on the rheostat. 1. Only clean ashes out of the stove when the CAUTION: Do not use chemicals for unit has cooled down. Remove the plug by fluids to start fire.
  • Page 30: Maintenance

    maintenance WARNING: Do not operate without CAUTION: DO NOT BURN GARBAGE either the Ash Plug properly seated OR FLAMMABLE LIQUIDS SUCH or the Ash Dump Plates screwed in AS GASOLINE, NAPTHA, OR place, excessive temperatures will ENGINE OIL. SOME FUELS COULD result.
  • Page 31: Creosote

    maintenance Maintenance Creosote Door Gasket It is very important to carefully maintain your When wood is burned slowly, it produces tar and If the door gasket requires replacement 7/8" diameter fireplace stove, including burning seasoned wood other organic vapours combine with moisture to material must be used.
  • Page 32: Secondary Air Tube Removal/Installation

    maintenance 3. Grasp secondary air tube firmly with vise grips, using a hammer tap vise Secondary Air Tube Removal/Installation grips from right to left until air tube is released from grip. Remove. 4. Remove top left and right metal retainers, followed by the fragile three 1.
  • Page 33: Vertical Stainless Deflector Replacement

    maintenance Vertical Stainless Deflector Replacement 7/16'' Nuts 7/16'' Bolts Slide right + down to remove. Reverse to replace. Vertical Deflector Remove 2 front air tubes 1. Remove 2 front secondary air tubes (page 31) / vermiculite baffles (page 25). 2. Loosen the two 7/16'' bolts + nuts to remove / replace vertical baffle. 3.
  • Page 34: Annual Maintenance

    maintenance Annual Maintenance Completely clean out entire unit Annually Inspect air tube and bricks Replace any damaged parts. Adjust door catch assembly If unable to obtain a tight seal on the door - replace door gasket seal. Readjust door catch after new gasket installed. Inspect condition and seal of: Glass Gasket Door Gasket...
  • Page 35: Parts List

    parts list Main Assembly Part # Description 075-070 Left Side Heat Shield 075-071 Right Side Heat Shield 075-040 Side Baffle Cover (Each) 075-058F Draft Control Lever 075-052 Bracket Probe 815-557 Rear Air Deflector 075-955 Baffle Complete Set (Center + Sides) 033-953 3/4 OD x 19-1/4 Airtube 3 Per Unit (Each) 846-570...
  • Page 36 parts list Main Assembly | F1150CSA Regency Freestanding Woodstove...
  • Page 37: Bottom Shield And Legs

    parts list Bottom Shield and Legs Part # Description 075-911 Bottom heat Shield 850-126 Black Cast legs (Set Of 4) 850-128 Nickel Cast legs (Set Of 4) 075-914 Ashdrawer Bottom Heat Shield 942-110 Ashplug 820-249 Ashplug Tool 075-079 Blanking Plate 905-008 5/16"...
  • Page 38: Complete Brick Kit

    parts list 075-960 F1150S Complete Brick Kit Fire bricks Size 4-1/4" x 7" 4-1/2" x 7" 9" x 4-1/2" 9" x 2" 3-1/2" x 4-1/2" (AD) 4-1/4" x 8" 3-1/2" x 2-1/4" Ashdump brick | F1150CSA Regency Freestanding Woodstove...
  • Page 39 notes F1150CSA Regency Freestanding Woodstove |...
  • Page 40: Warranty

    warranty Indoor Wood Product Warranty Limited Lifetime Warranty FPI Fireplace Products International Ltd. (for Canadian customers) and Fireplace Products U S, Inc. (for US customers) (collectively referred to herein as “FPI”) extends this Limited Lifetime Warranty to the original purchaser of this Appliance provided the product remains in the original place of installation.
  • Page 41 warranty The authorized selling dealer, or an alternative authorized FPI dealer if pre-approved by FPI, is responsible for all in- field diagnosis and service work related to all warranty claims. FPI is not responsible for results or costs of workmanship of unauthorized FPI dealers or agents in the negligence of their service work. At all times, FPI reserves the right to inspect reported in the field/on location complaints of products claimed to be defective before processing or authorizing any claim.
  • Page 42 warranty FPI has no obligation to enhance or modify any Appliance once manufactured (i.e. as products evolve, field modifications or upgrades will not be performed on existing Appliances). Any Appliance showing signs of neglect or misuse will not be covered under the terms of this warranty policy and may void this warranty, including Appliances with rusted or corroded fireboxes that have not been reported as rusted or corroded within three (3) months of installation/purchase.
  • Page 43: Warranty Registration Card

    warranty Warranty Registration Card Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 44 warranty | F1150CSA Regency Freestanding Woodstove...
  • Page 45: Recycling

    recycling PRODUCT LIFE CYCLE: By recycling your used appliances, you divert waste from your local landfills and help the environment. You also reduce the need for raw materials to manufacture new products. Contact your local municipality for appliance recycling services, local recycling programs, or appliance removal services to ensure your Regency appliance components, and packaging are properly recycled.
  • Page 46 notes | F1150CSA Regency Freestanding Woodstove...
  • Page 47 F1150CSA Regency Freestanding Woodstove |...
  • Page 48 nstaller: Please complete the following information Dealer Name & Address: _______________________________________ ___________________________________________________________ Installer: ___________________________________________________ Phone #: ___________________________________________________ Date Installed: _______________________________________________ Serial #: ____________________________________________________ Printed in Canada Regency is a trademark of FPI Fireplace Products International Ltd. © Copyright 2024, FPI Fireplace Products International Ltd. All rights reserved.

Table of Contents