Installation Manual French Manual Download: https://bit.ly/3qvWvSf www.regency-fire.com Manuel en Français : https://bit.ly/3qvWvSf MODEL: F3500 Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference.
Page 2
Note: Due to the high efficiency of the F3500 unit. Double wall pipe is recommended from the stove top to either wall or roof exit. A mini- mum of 36"...
CERTIFIÉ CONFORME AUX NORMES 2020 DU U.S. ENVIRONMENTAL PROTECTION AGENCY EN MATIÈRE D'ÉMISSION DE PARTICULES DE BOIS AVEC DU BOIS DE CORDE''. APPROUVÉ ASTM E3053. MODÈLE REGENCY F3500 – 0,9 G /H. CET AP- PAREIL DE CHAUFFAGE AU BOIS DOIT ÊTRE INSPECTÉ PÉRIODIQUEMENT ET RÉPARÉ POUR FONCTIONNER CORRECTEMENT.
6" Flue Collar 27-17/18" [710mm] 26" [660mm] 23" 22-3/4" Shown with optional fan [584mm] [578mm] ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS. F3500 Regency Freestanding Woodstove...
WARNING: ONLY USE SPECIFIED COMPONENTS. The following items are required when assembling your Regency Stove. F3500 unit - the Rear Heat Deflector is supplied with the stove, but if you choose not to use it you must use the Airmate instead.
The F3500 unit requires the pedestal attached holes in the has been selected. It stops the heat radiated from to the base. The F3500 stove requires either front bottom the flue collar from overheating the rear wall. The the Airmate or Rear Heat Deflector on top of the...
Note: Minimum alcove ceiling height - 83" (2108 mm) Vertical Termination} H = Maximum depth of alcove - 48" (1219mm) G= Minimum width of alcove - 60" (1524mm) ROOF EXIT NOTE: This clearance is also required for air space between the appliance and wall/ceiling. WALL EXIT F3500 Regency Freestanding Woodstove...
45º elbows be used instead of a 90º elbow to improve draft and performance. If not adhered to this, it will result in poor performance overfiring and or dangerous operating conditions which may void your warranty. F3500 Regency Freestanding Woodstove...
Cover opening with and support chimney section on both sides with 24 gage minimum sheet metal supports. See that the supports are fastened securely to wall surfaces on all sides. Make sure fasteners used to secure chimney flue liner. F3500 Regency Freestanding Woodstove...
5. Place the storm collar over the flashing, sealing the joints with a silicone caulking. 6. Fasten the raincap with spark screens (if required) to the top of your chimney. Horizontal Installation F3500 Regency Freestanding Woodstove...
11. WARNING: DO NOT INSTALL IN A SLEEPING ROOM OF A MOBILE HOME. 12. Use silicone to create an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the structure. F3500 Regency Freestanding Woodstove...
Mark the position of your unit as outlined in the "General Information" and "Clearances to Combustibles" section of the manual. Pipe fresh air into the pedestal area by using a minimum 4" duct pipe with a mesh grill at the outside termination. Rear View F3500 Regency Freestanding Woodstove...
Ensure positive location of the deflector prior to hand tightening. WARNING: Operation of the unit without proper installation of smoke deflector will void warranty. 3. Ensure deflector is seated so bolts are situated at the top of the opening before tightening. Hand tighten bolts only. F3500 Regency Freestanding Woodstove...
PREVIOUS REVISION F3500 MODEL # QTY. THIS DRAWING IS THE PROPERTY OF FPI LTD., IT MAY NOT BE COPIED IN WHOLE OR IN PART, OR DISCLOSED TO A THIRD PARTY WITHOUT OUR PRIOR WRITTEN CONSENT. Final Install F3500 Regency Freestanding Woodstove...
REMOVABLE DOOR HANDLE The F3500 has a removable door handle that can be stored when not in use. Hook Handle The cool to touch door handle is designed to be inserted from the bottom up and slide off when not held in place. Once in position, the door can be opened.
Wiring errors can cause improper and dangerous operation. Neutral Green Manual/ Live Ground Auto 120V AC Switch Switch 60 Hz Fan Thermodisc (normally open) Black Black Black Ground Wiring Diagram 908-126a 04/08/14 F3500 Regency Freestanding Woodstove...
Two dry pieces banged together sound hollow; wet pieces sound solid and dull. • Dry wood weighs much less than wet wood. • Split a piece of wood. If the exposed surface feels damp, the wood is too wet to burn. F3500 Regency Freestanding Woodstove...
- slide to the left to open, and to decrease fully open position. your wood stove up slowly! - slide to the right to close. The F3500 unit has To start a good and clean fire you will need 9. When re-fueling, always open bypass control, a secondary draft system that continually allows approx.
Modular Installation Options section. hardwoods, as compared to softwoods or to away from all combustible materials, pending green or freshly cut hardwoods. final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they F3500 Regency Freestanding Woodstove...
Burning coal will cause a sulfur-based compound to coat the catalyst. Revert to burning wood and fire the combustor to elevated temperatures for one hour. F3500 Regency Freestanding Woodstove...
(by- 15.200 A clean flue helps prevent chimney flue fires. pass open) through the combustor. 14.000 F3500 Flameguard & Catalyst F3500 Regency Freestanding Woodstove Mass = 4.649 pounds TOTAL AREA FOR AIR FLOW = 37.396 3RD ANGLE...
NOTE: Replacement combustors can be retrieved from Applied Ceramics or Contact your local Regency Dealer for details. DO NOT OPERATE THE APPLIANCE IF COMBUSTOR BECOMES INACTIVE - DO NOT OPERATE WITHOUT COMBUSTOR. F3500 Airtube Replacement F3500 Regency Freestanding Woodstove...
6. Reverse steps to reinstall - ensure the pass rod is seated with the channel on the pass door. (Unit viewed as transparent to facilitate view) Channel Pass rod Loosen 3 rear nuts F3500 Damper Assembly Draft F3500 Regency Freestanding Woodstove...
Note: If air tube is locked into place correctly there should be slight movement when moving the air tube back and forth. 5. Reverse steps to reassemble stove. F3500 Regency Freestanding Woodstove...
To remove a shim, loosen the 2 bolts to create clearance behind catch. Place top bolts. a screwdriver in the slot of the shim and slide out. Retighten bolts. Note: Keep the shims - they may be required in the future when the gasket is replaced. Door Hinge bolts F3500 Regency Freestanding Woodstove...
Allow it to set, then tap or vibrate the screw or bolt to help loosen it before attempting to remove it. For best results, follow the instructions that are provided with the penetrating oil. F3500 Regency Freestanding Woodstove...
F3500 STOVE BRICK LAYOUT 042-960 Brick Set Complete Fire bricks Size 4-1/2" x 9" 4" x 9" 3-1/2" x 4-1/2" 1-3/4" x 4-1/2" 4-1/2" x 7-5/8" 1-3/4" x 9" 802-146 1.750 x 9.000 BRICK 802-165 7.375 x 4.500 CUT BRICK 802-128 1.875 x 4.500 BRICK...
DOOR ASSEMBLY Part # Description Part # Description 042-520 Door cast black (F3500) 846-530 5/8" Medium Door gasket kit 106-541/P Aligner assembly 042-021 Gasket bracket 156-514 Removable cast handle assembly 904-513 Hex bolt 1/4-20 x 3/4 LG. 940-416/P...
At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective prior to processing or authorizing of any claim. Failure to allow this upon request will void the warranty. Revision Date: July 2019 Regency Wood Products Warranty F3500 Regency Freestanding Woodstove...
Page 37
Freight damages for products or parts are not covered under the terms of the warranty. Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Revision Date: July 2019 Regency Wood Products Warranty F3500 Regency Freestanding Woodstove...
Page 38
To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx within ninety (90) days of purchase. F3500 Regency Freestanding Woodstove Revision Date: July 2019 Regency Wood Products Warranty...
Page 39
For fireplace care and tips and answers to most common questions please visit our Customer Care section on our Web Site. Please feel free to contact your selling dealer if you have any questions about your Regency product. F3500 Regency Freestanding Woodstove...
Page 41
NO LABOR WILL APPLY. All warranty claims must be sent to: Regency Fireplace Products By Authorized Regency Dealer * Prices subject to change.
Need help?
Do you have a question about the F3500 and is the answer not in the manual?
Questions and answers