Page 24

LOADING A PROGRAM

There are two functions for loading a program; LOAD INTERNAL, and LOAD CARTRIDGE.
These functions are used to copy a wire list program from a memory location into the working
memory. The program in working memory will be over-written by the program being loaded.
If the program in working memory is to be retained for future use, save it by means of the Saving
a Program procedure before performing this procedure.
Turn power off before removing or inserting the program cartridge.
A complete Load procedure is provided below: To select and load a program, proceed as
follows:
1. Press Up or Down arrow to step through the menu to display either LOAD
INTERNAL or LOAD CARTRIDGE.
2. Press MENU RUN to initiate the selected function, and the display will show the
selected Load function and the signature for the last program that was selected
with the load function:
3. Press Up or Down arrow to display the signature for the program to be loaded into
the working memory. Each time the arrow is pressed, the next program signature
will display.
4. If it is decided not to load the program, press RESET.
5. When the desired program signature is reached, press MENU RUN and the
program will be copied into the working memory.
NOTE:
Load Int (signature #)
or
Load Cart (signature #)
Model 64/64x2 Instruction Manual