Printer Hookup - Cablescan 64 Instruction Manual

Continuity tester
Table of Contents

Advertisement

Model 64/64x2 Instruction Manual

PRINTER HOOKUP

An RS 232C (PRINTER/SERIAL) port provided on the rear panel (Figure 1) accommodates an
80-column serial printer.
1. Prepare printer for use and connect it to its proper power source, in accordance
with the printer manufacturer's manual.
2. Connect printer interface cable to the PRINTER/SERIAL port on the rear panel of
Model 64.
3. On the printer, turn printer switch ON, and press SELECT switch.
4. Set Model 64 power ON/OFF switch to ON.
5. Press the Up or Down arrow to step through the menu to reach SET BAUD RATE.
6. Press MENU RUN to initiate setting the baud rate.
7. If the display reads "Baud Rate 1200," press RESET to continue.
8. If the display shows: "Baud Rate 9600," press the Down arrow to change to 1200,
and then press MENU RUN.
If the printer was not provided by Cablescan, the following setup data are
required:
Transmission to the printer is at 1200 Baud, with 8 data bits, 1 stop bit, and no parity. Pin
assignments are as follows:
∗ LOW level on pin 11 from the printer indicates printer is ready
to receive data. HIGH level signals tester to stop sending data.
PIN
ASSIGNMENT
3
Data Out
7
Signal Ground
* 11
Clear to Send
Page 9