5.19 Temperature Sensor

Measured on the TI CC2650EM-5XD reference design with T
PARAMETER
Resolution
Range
Accuracy
(1)
Supply voltage coefficient
(1) Automatically compensated when using supplied driver libraries.

5.20 Battery Monitor

Measured on the TI CC2650EM-5XD reference design with T
PARAMETER
Resolution
Range
Accuracy

5.21 Continuous Time Comparator

T
= 25°C, V
= 3.0 V, unless otherwise noted.
c
DDS
PARAMETER
Input voltage range
External reference voltage
Internal reference voltage
Offset
Hysteresis
Decision time
Current consumption when enabled
(1) Additionally, the bias module must be enabled when running in standby mode.
Copyright © 2015–2016, Texas Instruments Incorporated
TEST CONDITIONS
TEST CONDITIONS
TEST CONDITIONS
DCOUPL as reference
Step from –10 mV to 10 mV
(1)
Submit Documentation Feedback
Product Folder Links:
SWRS158B – FEBRUARY 2015 – REVISED JULY 2016
= 25°C, V
= 3.0 V, unless otherwise noted.
c
DDS
= 25°C, V
= 3.0 V, unless otherwise noted.
c
DDS
CC2650
CC2650
MIN
TYP
MAX
UNIT
4
°C
–40
85
°C
±5
°C
3.2
°C/V
MIN
TYP
MAX
UNIT
50
mV
1.8
3.8
13
mV
MIN
TYP
MAX
UNIT
0
VDDS
0
VDDS
1.27
3
mV
<2
mV
0.72
µs
8.6
µA