7.1

Standard System (Optional PCB not connected)

THt
Mono Bloc
Unit
HEX
Addtional
Outdoor Sensor
7.2

Advance System (Optional PCB connected)

DHW Tank
THt
DHW Tank
Mono Bloc
Unit
HEX
T
Addtional
Outdoor Sensor
DHW Tank
3-Way valve
DHW Tank
Air purge
valve
Heater
Expansion
Vessel (10L)
T
Cold Water
Supply
Buffer
Tank
Thermistor
3-Way valve
Air purge
valve
Heater
Expansion
Vessel (10L)
Boiler
Room Thermo (4 option)
Cold Water
Supply
External
Thermostat
T
External
Thermistor
3-Way valve
Extra Pump
Mixing
Valve
Solar
Panel
Thermistor
Mixing
Valve
39
Internal
Thermostat
Nothing
2-Way valve
Zone1
Fan Coil Unit
Water Temp
(Heating / Cooling)
Pump
Thermistor
2-Way valve
Panel Heater Unit
(Heating)
Floor Heating Panel
Zone2
Fan Coil Unit
Water Temp
(Heating / Cooling)
Thermistor
Pump
2-Way valve
Panel Heater Unit
(Heating)
Floor Heating Panel
Either Zone2 Heat & Cool or Pool Heating
Hex
Pool
Pump
Thermistor
Fan Coil Unit
(Heating / Cooling)
Panel Heater Unit
(Heating)
Zone1
Room Thermo (4 option )
External
Internal
Thermostat
Thermostat
T
External
Without
Thermistor
Zone2
Room Thermo (4 option )
External
Internal
Thermostat
Thermostat
T
External
Without
Thermistor
Pool