Panasonic WH-MXC09J3E8 Service Manual page 161

Air-to-water heatpump
Hide thumbs Also See for WH-MXC09J3E8:
Table of Contents

Advertisement

17.5.12
Abnormal Zone 2 Sensor (H44)
Malfunction Caused:
1
Faulty connector connection.
2
Faulty buffer tank sensor.
3
Faulty indoor sub PCB.
Abnormality Judgment:
Continue for 5 seconds.
Abnormal zone 2 sensor
Turn off power check connector connection normal?
Plug out from sub PCB, check sensor characteristics measure
resistance is it match?
Change PCB
YES
YES
Caution
Correct abnormal connection
NO
Change sensor zone 2
161
For safety reason and to prevent
component breakdown, always switch
off the power before remove and
connect the component.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wh-mxc12j9e8

Table of Contents