12.1.4.3
Connecting Requirement
For model WH-MXC09J3E8
The equipment's Power Supply 1 complies with IEC/EN 61000-3-2.
The equipment's Power Supply 1 complies with IEC/EN 61000-3-3 and can be connected to current supply
network.
The equipment's Power Supply 2 complies with IEC/EN 61000-3-2.
The equipment's Power Supply 2 complies with IEC/EN 61000-3-11 and shall be connected to suitable supply
network, with the following maximum permissible system impedance Z
Please liaise with supply authority to ensure that the Power Supply 2 is connected only to a supply of that
impedance or less.
For model WH-MXC12J9E8, WH-MXC16J9E8
For model WH-MXC12J9E8, the equipment's Power Supply 1 complies with IEC/EN61000-3-2.
For model WH-MXC16J9E8, the equipment's Power Supply 1 complies with IEC/EN61000-3-12 provided that the
short-circuit power Ssc is greater than or equals to 550kVA at the interface point between the user's supply and
the public system.
It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution
network operator if necessary that the equipment is connected only to supply with a short-circuit power Ssc
greater than or equals to 550kVA.
The equipment's Power Supply 1 complies with IEC/EN 61000-3-3 and can be connected to current supply
network.
The equipment's Power Supply 2 complies with IEC/EN 61000-3-2.
The equipment's Power Supply 2 complies with IEC/EN 61000-3-3 and can be connected to current supply
network.
12.1.4.4
Wire Stripping and Connecting Requirement
Wire stripping
Terminal
board
5 mm or
more
(gap between wires)
No loose strand
when insert
For model WH-MXC09J3E8
Terminal on the Mono bloc unit
(Power Supply Cord)
Terminals on the isolating device
from power supply
(Disconnecting means)
For model WH-MXC12J9E8, WH-MXC16J9E8
Terminal on the Mono bloc unit
(Power Supply Cord)
Terminals on the isolating device
from power supply
(Disconnecting means)
Conductor
Conductor
Conductor not
fully insert
over insert
ACCEPT
PROHIBITED
L
L
L
N
L
A1
A2
A3
L
L
L
N
L
A1
A2
A3
Power Supply 2
Power Supply 1
L
L
L
N
L
A1
A2
A3
L
L
L
N
L
A1
A2
A3
Power Supply 1
fully insert
Terminal screw
M4
M5
*1 - Earth wire must be longer than other cables
PROHIBITED
for safety reasons.
55
N
1
1
N
1
1
L
L
N
B1
B2
B3
L
L
N
B1
B2
B3
Power Supply 2
= 0.426 ohm(Ω) at the interface.
max
Tightening torque
cN•m {kgf•cm}
157~196 {16~20}
196~245 {20~25}
Power Supply Cord
*1