Kohler KD62V12 Operation And Maintenance Manual page 88

Hide thumbs Also See for KD62V12:
Table of Contents

Advertisement

Maintenance
Service level definition
Component
Recommended:
SL106
Fuel prefilters
Crankcase Breather
SL107
Filters
Recommended: Air
SL108
filters + Air ducting
SL109
Alternator belt
Alternator belt
SL110
tensioner
Coolant drain points
SL116
(Glysantin G48)
Tab. 21: Service level 1 — PRP — Basic maintenance - Version : 2018/07-2
88
Service
Schedule
Type
1000
2Y
X
7500
2Y
X
3000
2Y
X
1500
2Y
X
1500
18Y
6000
4Y
X
© 2019 by Kohler Co. All rights reserved.
Operation and Maintenance Manual
Task description
Replace primary fuel filter cartridge.
See the operator and maintenance manual of your
application.
Replace primary fuel filter cartridge.
See the operator and maintenance manual of your
application.
Replace the air filter and clean air ducting between
air filter and compressor.
See the operator and maintenance manual of your
application.
Inspect conditions of drive belt and fit new one if
necessary.
(For more information see: 5.6.4 Checking
X
drive belt — SL109, page 96)
(For more information see: 5.6.5 Replacing V-ribbed
belt — SL 109, page 97)
Visual inspection of the tensioner. Replacement if
X
necessary.
(For more information see: 5.6.6
Replacing tensioning device — SL110, page 98)
Replace coolant (at least every 4 years for coolant
formulated with Glysantin G48).
Respect fluids and lubricants specifications.
Note: for coolant formulated with Glysantin G40, the
extension up to 8000h/6Y is possible after analysis.
(For more information see: 5.8.5 Coolant drain points
— SL116, page 115)
. Check belt tension.
.
.
KD62V12 33521030301_6_1 EN_US
.
2019-02

Advertisement

Table of Contents
loading

Table of Contents