Kohler KD62V12 Operation And Maintenance Manual page 149

Hide thumbs Also See for KD62V12:
Table of Contents

Advertisement

Operation and Maintenance Manual
SPN
1180
1180
1181
3245
1180
3279
1181
94
174
94
174
94
94
94
174
174
174
174
516195
190
729
729
729
729
516304
729
516305
730
730
730
730
516344
730
KD62V12 33521030301_6_1 EN_US
2019-02
FMI
2
Exhaust boost temperature (CMR sensor) - Communication error
2
Exhaust boost temperature 1 (CMR sensor) - Communication
error
2
Exhaust boost temperature 2 (CMR sensor) - Communication
error
0
Exhaust temperature before turbocharger 1 - Critical overtemper-
ature
15
Exhaust temperature before turbocharger 1 - Overtemperature
warning
0
Exhaust temperature before turbocharger 2 - Critical overtemper-
ature
15
Exhaust temperature before turbocharger 2 - Overtemperature
warning
0
Fuel supply - Critical overpressure
0
Fuel supply - Critical overtemperature
1
Fuel supply - Critical underpressure
15
Fuel supply - Overtemperature warning
3
Fuel supply pressure sensor - Short circuit to battery
4
Fuel supply pressure sensor - Short circuit to ground or open
circuit
31
Fuel supply pressure sensor - Supply voltage out of range
5
Fuel temperature sensor - Open circuit
3
Fuel temperature sensor - Short circuit to battery
4
Fuel temperature sensor - Short circuit to ground
31
Fuel temperature sensor - Supply voltage out of range
2
Generator Set Controller - Communication error
0
Genset - Engine over speed
6
Heating flange 1 - Critical high output current
11
Heating flange 1 - Electrical error
5
Heating flange 1 - Open circuit
3
Heating flange 1 - Short circuit to battery high side
3
Heating flange 1 - Short circuit to battery low side
4
Heating flange 1 - Short circuit to ground high side
4
Heating flange 1 - Short circuit to ground low side
6
Heating flange 2 - Critical high output current
11
Heating flange 2 - Electrical error
5
Heating flange 2 - Open circuit
3
Heating flange 2 - Short circuit to battery high side
3
Heating flange 2 - Short circuit to battery low side
4
Heating flange 2 - Short circuit to ground high side
© 2019 by Kohler Co. All rights reserved.