5.8.3 Inspecting low temperature circuit (charge air cooler) — SL002
Fig. 72: Low Temperature circuit drain holes
At drain holes 1:
u Check for leakage.
In case of water leakage:
u The leakage of condensation water is not an issue. Let the condensation water flows out.
In case of air leakage:
u Air leakage is normal.
In case of water mixed with antifreeze leakage:
u Inspect charge air cooler for leaks. If necessary, have the leaks repaired by the competent
personnel.
KD62V12 33521030301_6_1 EN_US
2019-02
© 2019 by Kohler Co. All rights reserved.