REMOVING & REFITTING OF THE GLASS FRAME (Continued)
a)
Remove the 2 screws which hold the pilot shield in place. (see fig. 15)
b)
Remove the top infill panel by sliding it upwards out of the clips.
c)
With the allen key provided remove the 4 allen bolts, loosening each
one a small amount at a time to prevent stressing the glass panel, then
lift the glass frame clear.
d)
Assemble ceramic fuel-bed and coals as shown in section three.
e)
Refit the glass panel to the fire in reverse order, again tightening each
allen bolt a small amount at a time to prevent stressing the glass panel.
f)
Fit the allen key to the bracket which is situated at the bottom left hand
corner of the firebox, and advise the customer of the position of the
allen key.
NOTE : Always ensure that a consistent seal between the combustion cham-
ber and the glass frame is achieved.
ASSEMBLING FUEL BED AND COMMISSIONING

3.1 FITTING THE FUELBED

a)
Place the fuel-bed centrally onto the fuel-bed support. Ensure that the
fuel-bed is located centrally in the firebox, and that the front outside
face of the left and right hand fuel-bed legs are touching the stainless
steel fibre support trims. See Fig. 16
Fig. 16
SECTION 3