4. Mounting Procedure

1. Cut the hole cover on the cover on the right
side of the amplifier unit with nippers, etc. to
expose the connector. When cutting, take
care not to scratch the board.

5. Maintenance and Inspection

Carry out daily and periodic inspection to prevent failures beforehand, and to ensure continued high-reliability operation.
Lengthy use of the product without inspection could result in failure and damage, or accident and fire.
■ Daily inspection
Conduct a visual check during operation to verify whether there are any abnormalities. Normally, the following inspections
should be carried out.
1) Has a significant amount of dust accumulated on the servo amplifier?
2) Does the ambient environment (temperature, power supply, etc.) satisfy the specifications?
3) Are there any LED display abnormalities?
4) Are there any abnormal noises, abnormal vibrations, or abnormal odors?
5) Are there any abnormalities such as signs of overheating or discoloration?
■ Periodic inspection
Carry out periodic inspection after stopping operation and turning OFF the power. It takes time for the main circuit DC part
smoothing capacitor to dissipate even after turning OFF the power. Always carry out inspection after ensuring that the
charge LED is OFF. A periodic inspection cycle of 1 year is recommended, however, the cycle may be shorted depending on
the usage conditions.
Inspection
Inspection item
location
● Check the ambient temperature, humidity, vibration, and
Ambient
environment
atmosphere (presence of dust, gas, oil mist, water
droplets, etc.)
● Have any foreign objects such as tools, or dangerous
objects been left in the surrounding area?
● Is the interface power supply voltage normal?
Power supply
voltage
● Is the display difficult to see? Does it light up correctly?
LED display
● Is there any fixing screw looseness?
Connectors,
wiring
● Is there any damage?
● Is there any looseness or wire disconnection at crimped
parts?
● Are the internal safety circuits functioning properly?
Internal circuits
CAUTION : Safety standards stipulate that inspection is
2. Align the 2 protrusions on the option with the
holes on the right side of the amplifier unit,
and secure temporarily so that the front
surface is flush.
required every 3 months.
3. Tighten screws (1) to (4) with a driver.
4. Tighten the provided screw (5) with a driver.
Tightening torque : 0.7 N・m
Inspection method
● Perform a visual check,
and perform
measurement with the
respective meters.
● Perform a visual check.
● Perform measurement
with a tester, etc.
● Perform a visual check.
● Tighten further.
● Perform a visual check.
● Turn the power ON
again.
● Turn the input terminals
ON and OFF.
Criteria
● The specifications
should be satisfied.
● There should be no
objects lying around.
● The specifications
should be satisfied.
● There should be no
abnormalities.
● There should be no
abnormalities.
● No alarm should occur.

Advertisement