Related Parameters; Power-On Sequence - Fuji Electric ALPHA7 Series Instruction Manual

Ac servo amplifier, function safety module
Hide thumbs Also See for ALPHA7 Series:
Table of Contents

Advertisement

3.5 Related Parameters

Parameter
Name
SF00
SS1 level
SF01
SS1 timer
SF02
SS1 deceleration time
SF03
SS1 upper limit width
SF04
SS1 monitoring mode
SF05
SLS level
SF06
SLS timer
SF07
SLS deceleration time
SF08
SLS upper limit width
SF09
SSM selection
SF10
SSM level
SF11
SBC function selection
SF12
SIA terminal function selection
SF13
SIB terminal function selection
SF14
Motor reference speed
SF15
The upper limit speed latency
SF16
For manufacturer
SF17
Encoder selection
SF18
Restart selection
SF19
For manufacturer
SF20
EDM1 output selection
SF21
EDM2 output selection
SF22
Safety option ID
3.6 Power ON Sequence
This module conducts an initial diagnosis of internal circuits when the power supply is started. The diagnosis time will vary
depending on the safety functions used, and therefore caution is required. The maximum length of time from the point the
control power is turned ON until initial diagnosis is complete is 4.5 seconds. The fewer the safety functions used, the shorter
the time.
Turn ON the external power supply (24 VDC) connected to this option before turning ON the servo amplifier power supply. If
the servo amplifier starts up with the external power supply OFF, a circuit error will be determined by the safety circuit
self-diagnosis function, and an alarm will occur.
Setting range
0 to 6000 [r/min]
0.01 to 99.99 [s]
0.01 to 99.99 [s]
0 to 6000 [r/min]
0: Speed monitoring, 1: Time monitoring
100 to 6000 (r/min)
0.01 to 99.99 [s]
0.01 to 99.99 [s]
0 to 6000 [r/min]
0: Not used, 1: Used
0 to 6000 (r/min)
0: Disable, 1: Enable
0: No selection, 1: SS1, 2: SLS, 3: SBC_FB
0: No selection, 1: SS1, 2: SLS, 3: SBC_FB
1 to 6000 [r/min]
0.00 to 99.99 [s]
-
0: Not recommended, 1: Recommended
0: Disable, 1: Enable
-
0: Pattern F, 1: Pattern Y, 2: SS1 operation
3: SLS operation, 4: SBC operation
0: Pattern F, 1: Pattern Y, 2: SS1 operation
3: SLS operation, 4: SBC operation
0 to 9999 (BCD code)
Default value
(Factory default)
150
10.00
1.00
150
0
150
10.00
1.00
150
0
150
0
0
0
1500
1.00
-
1
1
100
0
1
0000