IQ7-60-2-US Microinverter Specifications

Topic
Commonly used module pairings
Peak power tracking voltage
Operating voltage range
Maximum input DC voltage
Minimum / maximum start voltage
Maximum DC input short circuit current (module Isc)
Overvoltage class DC port
DC Port backfeed under single fault
PV array configuration
Maximum continuous AC output power (-40C to +65C)
Peak output power
Power factor (adjustable)
Nominal AC output voltage range
240 VAC (single phase)
208 VAC (single phase)
Nominal output current
240 VAC (single phase)
208 VAC (single phase)
Nominal frequency
Extended frequency range
Maximum AC output over current protection device
AC short circuit fault current over 3 cycles
1
No enforced DC/AC ratio. See the compatibility calculator at
2
Nominal Voltage Range can be extended if required by the utility.
31
Enphase IQ7-60-2 Microinverter Parameters
DC Parameters
1
AC Parameters
2
© 2018 Enphase Energy Inc. All rights reserved.
IQ 7 / IQ 7+ / IQ 7X Micro Installation and Operation
Unit
V
V
V
V
A
A
1x1 ungrounded array; No additional DC side protection
required; AC side protection requires max 20A per branch
VA
VA
Vrms
Vrms
Arms
Arms
Hz
Hz
A
A rms for over 3 cycles
enphase.com/en-us/support/module-compatibility
Min
Typical
Max
235 W – 350+ W
27
16
22
II
circuit
240
250
0.7 leading
0.7 lagging
211
264
183
229
1.0
1.15
60
47
20
5.8 Arms
141-00043-01
37
48
48
48
15
0
68