ε
Media group
DC (
r)
1
1.4...1.6
2
1.6...1.9
3
1.9...2.5
4
2.5...4
5
4...7
> 7
6
16

3.3 Function "medium property" (003)

This function is used to select the dielectric constant.
Selection:
• unknown
• 1.4 ... 1.6
FMP40: for coaxial and Rod probe with installation in metallic pipes < DN 150
FMP41C, FMP45: 1,4 for installation in metallic pipes
• 1.6 ... 1.9
• 1.9 ... 2.5
• 2.5 ... 4.0
• 4.0 ... 7.0
• > 7.0
FMP40:
Typical bulk solids
– Plastic granulate
– White lime, special cement
– Sugar
– Portland cement, plaster
– Grain, seeds
– Ground stones
– Sand
– Naturally moist (ground)
stones, ores
– Salt
– Metallic powder
– Carbon black
– Coal
Typical liquids
– Condensed gases, e.g. N
, CO
2
– Liquefied gas, e.g. Propane
– Solvent
– Frigen / Freon
– Palm oil
– Mineral oils, fuels
– Benzene, styrene, toluene
– Furan
– Naphthalene
– Chlorobenzene, chloroform
– Cellulose spray
– Isocyanate, aniline
– Aqueous solutions
– Alcohols
– Ammonia
Typical measuring range
bare metallic probes
4 m / 157", only coax
2
probe
25...30 m /
984...1181"
30...35 m /
15...25 m / 590...984"
1181...1378"
35 m / 1378"
35 m / 1378"
35 m / 1378"
Endress+Hauser
Levelflex M
PA-coated rope
probes
12,5...15 m /
492...590"
25...30 m /
984...1181"
35 m / 1378"
35 m / 1378"