Performance Charts

Performance Charts
Pressure Chart
120
(8.3, 0.83)
100
(6.9, 0.69)
80
(5.5, 0.55)
60
(4.1, 0.41)
40
(2.8, 0.28)
20
(1.4, 0.14)
0
0
20
(76)
(Pump tested in water with inlet submerged)
Flow Chart
150
180
(10.3, 1.03)
(5.10
125
150
(8.6, 0.86)
(4.25)
100
120
(6.9, 0.69)
(3.40
75
90
(5.2, 0.52)
(2.55)
50
60
(3.4, 0.34)
(1.70)
25
30
(1.7, 0.17)
(0.85)
0
0
20
(76)
(Pump tested in water with inlet submerged)
To find Fluid Outlet Pressure (psi/bar/MPa) at a
specific fluid flow (gpm/lpm) and operating air pressure
(psi/bar/MPa):
1. Locate fluid flow rate along bottom of chart.
2. Follow vertical line up to intersection with selected
operating air pressure curve.
3. Follow left to scale to read fluid outlet pressure.
30
D
C
B
A
40
60
80
100
(151)
(227)
(303)
(379)
FLUID FLOW gpm (lpm)
D
C
B
A
40
60
80
100
(151)
(227)
(303)
(379)
FLUID FLOW gpm (lpm)
120
140
160
(454)
(530)
(606)
120
140
160
(454)
(530)
(606)
To find Air Consumption (scfm or m
fluid flow (gpm/lpm) and air pressure (psi/bar/MPa):
1. Locate fluid flow rate along bottom of chart.
2. Read vertical line up to intersection with selected
operating air pressure curve.
3. Follow left to scale to read air consumption.
OPERATING AIR PRESSURE
A 40 psi air (2.8 bar, 0.28 MPa)
B 70 psi air (4.8 bar, 0.48 MPa)
C 100 psi air (7 bar, 0.7 MPa)
D 120 psi air (8.62 bar, 0.86 MPa)
OPERATING AIR PRESSURE
A 40 psi air (2.8 bar, 0.28 MPa)
B 70 psi air (4.8 bar, 0.48 MPa)
C 100 psi air (7 bar, 0.7 MPa)
D 120 psi air (8.62 bar, 0.86 MPa)
3
/min) at a specific
3A8693B