Technical Specifications - Graco Aluminum Husky 2150 LP Instructions Manual

Air-operated diaphragm pumps
Hide thumbs Also See for Aluminum Husky 2150 LP:
Table of Contents

Advertisement

Technical Specifications

Technical Specifications
Husky 2150 LP Air-Operated Diaphragm Pumps
Maximum fluid working pressure
Air pressure operating range*
Maximum air consumption
Air consumption at 70 psi/60 gpm
Maximum free-flow delivery
Maximum pump speed
Maximum size pumpable solids
Environmental temperature range
Maximum suction lift
Dry
Wet
Fluid flow per cycle*
Standard Diaphragms
Noise (dBa)
Maximum sound pressure
Inlet/Outlet Sizes
Air inlet size
Air exhaust port size
Fluid inlet size
Fluid outlet size
Materials of Construction
Wetted materials on all models
Weight
All models
Notes
*
Startup pressures and displacement per cycle may vary based on suction condition, discharge head, air
pressure, and fluid type.
Sound pressure measured 3.28 feet (1 meter) from equipment. Sound power measured per ISO-9614-1.
All trademarks or registered trademarks are the property of their respective owners.
32
US
120 psi
20–120 psi
175 scfm
60 scfm
150 gpm
145 cycles per minute
1.8 in.
–4° to 140°F
20 ft
30 ft
1 gallon
90 dBa at 100 psi (0.69 MPa, 6.9 bar) at 50 cpm
2-11.5 in. npt(f) or 2-11 in. bspt(f)
2-11.5 in. npt(f) or 2-11 in. bspt(f)
76 lb
Metric
0.83 MPa, 8.27 bar
0.14–0.83 MPa, 1.38–8.27 bar
3
4.95 m
/minute
3
1.7 m
/minute
568 lpm
46 mm
–20° to 60°C
6.10 meters
9.14 meters
3.79 liters
1/2 in. npt(f)
3/4 npt(f)
Aluminum
34.47 kg
3A8693B