Transmit Power
(Mbps)
1 to 11
Receive
Sensitivity
(Mbps)
Remote
Telnet and SSH, Web GUI (http) and SSL (https), TFTP
Configuration
SNMP v1, v2c and v3
Support
SNMP trap and Syslog
PVES (ProximVision ES Network Management Systems)
Message
802.11i AES message authentication with 128 bit keys
Authentication
TKIP with 128 bit Michael Message Integrity Check
Intrusion
Detect MIC intrusion attacks
detection
Dimensions
6.69 x 6.69 x 1.74 in. (170 x 170 x 44.1 mm)
(L x W x H)
Weight
0.340 kg (0.75 lbs)
Environmental
Operating Temperatures:
0 to 45ºC
5 to 95 percent (non-condensing)
Storage Temperature:
- 40º to 70ºC
MTBF
>100,000 hrs
Warranty
One year parts/labor
®
ORiNOCO
802.11n & 802.11ac Access Points - Hardware Installation Guide
11b
Data
Transmission
Rates
Power*
(dBm)
20
* Combined Tx Power values
* MCS refers to Modulation Coding Scheme.
11b
Data
Receive
Rate
Sensitivity
(2.4-5Ghz)
1
-93
11
-90
* MCS refers to Modulation Coding Scheme.
AP-8100
11a/g
Data
Transmission
Rates
Power*
(Mbps)
(dBm)
6 to 48
54
AP-8100
11a/g
Data
Receive
Rate
Sensitivity
(Mbps)
(2.4-5Ghz)
6
-90
54
-75
Hardware Specifications
Data Rate
(MCS*)
20
MCS (0 to 5)
MCS 6
20
MCS 7
11n
Data
Receive Sensitivity
Rate
(2.4/5Ghz)
(MCS*)
20 MHz
MCS 0
-87
MCS 7
-70
11n
Transmission
Power*
(dBm)
20
19
17
40 MHz
-86
-66
38

Advertisement