Power Supply
Model: PWS-601-1H, 600 W AC multi-output power supply with PFC; 80 Plus Gold Certified
AC Voltage
100-240 V, 50-60 Hz, 7.5-3.1 A
+5 V: 20 A
+5 V standby: 3 A
+12 V: 49 A
+3.3 V: 16 A
Operating Environment
Operating Temperature: 0 ºC to 50 ºC (32 ºF to 122 ºF)
Non-operating Temperature: -40 ºC to 70 ºC (-104 ºF to 158 ºF)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class B, EN 55032 Class B, EN 61000-3-2/3-3, CISPR 32 Class B
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6,
EN 61000-4-8, EN 61000-4-11)
Other: VCCI-CISPR 32 and AS/NZS CISPR 32
Environmental: Directive 2011/65/EU, Delegated Directive (EU) 2015/863, and Directive 2012/19/EU
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe)
Perchlorate Warning
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products
containing CR (Manganese Dioxide) Lithium coin cells. "Perchlorate Material-special handling may apply. See
www.dtsc.ca.gov/
hazardouswaste/perchlorate"