Menu Delete
12
Menu Info
13
Backup / Restore
Plug-in the memory in the proper receiver connector
E R O N E
X P L 1 V
14
Memorization Plus
The memorization PLUS allows to add a new transmitter remotely, without using the push-buttons P1 & P2. It's enough to use a transmitter «Ma-
ster».
A transmitter «Master» can be :
1) the first transmitter added;
2) any transmitter memorized and changed as «master» using the Add Master submenu ;
The PLUS feature can be : ON, Limited or OFF
Plus ON : remote transmitter memorization enabled;
Plus Limited : remote transmitter memorization enabled only using a TX «master» ( see fig. 7 );
Plus OFF : remote transmitter memorization disabled;
NOTE : If the option «PLUS LIMITED» is set, the transmitter which «opens» the memorization can be only the first transmitter memorized.
If the option PLUS is OFF the remote memorization is disabled.
If the option PLUS is ON the remote memorization of a new transmitter can be done using any transmitter already in memory.
The memorization PLUS is active only if there is, at least, one transmitter in the memory. When the memory is empty, the memorization of the first
transmitter can be effected only using the buttons P1 and P2.
The warranty period for this product is 60 months, beginning from the manufacturer date. During this period, if the product does not
work correctly, due to a defective component, the product will be repaired or substituted at our discretion. The guarantee does not
cover the plastic container integrity. After-sale service is supplied at the factory.
Manufactured by : CDVI Wireless SPA - Via Piave, 23 - 31020 S.Pietro di Feletto (TV) - Italy
The installer's choice
Delete TX :
Delete a transmitter. It's necessary to have the transmitter available because the
system requires the RF transmission;
Delete Button :
Delete the single button of a transmitter;
Delete by List :
Delete a transmitter from a list. In this case it is enough to know the S/N of the transmitter
to be deleted to finalize the cancellation;
Delete All TX :
Delete all transmitters;
Delete setting :
Reset to factory default: delete all the transmitters and reset the relay operating mode
to PULSE.
For all the options, use P2 to scroll and P1 to confirm
Info relay :
Display relay operating mode
Info N. Users :
Display number of Tx memorized
Info List :
List of Transmitters
Info Version :
SW release.
For all the options, use P2 to scroll and P1 to confirm
Allows to create a backup of the memory data-base and save it onto an external
memory ( type SEL2641-MXPL) ( fig. 6)
Fig. 6
!
GUARANTEE
Tel : +39-0438-450860 - Fax : +39-0438-455628
web: www.erone.com - email: info@erone.com
Manufacturing Access Control since 1985
(*) Attention : this operation will overwrite all data of the internal memory
Fig.7
MEM.
Internal
Save
MEM.
Internal
Restore (*)
(*) : Push the button of the new
transmitter before the end of
the beep.
MEM.
External
MEM.
External