Section 5: Troubleshooting; General Troubleshooting - Generac Power Systems MAGNUM MLT6SM Owner's Manual

Light tower
Table of Contents

Advertisement

Section 5: Troubleshooting

General Troubleshooting

WARNING
Risk of burns. Allow engine to cool before
draining oil or coolant. Failure to do so could
result in death or serious injury.
Some of the more common problems are listed in the
table below. This information is intended to be a check or
verification that simple causes can be located and fixed.
It does not cover all types of problems. Refer to the OEM
engine operator's manual for additional troubleshooting
information. Procedures that require in-depth knowledge
or skills should be referred to a GMP ASD.
Problem
Low oil pressure
shutdown
High coolant
temperature shutdown
Unit cranks, but will not
start
If problems persist, contact Generac Mobile Products, LLC at 1-800-926-9768 for assistance.
Owner's Manual for MLT6SM/6SK Light Tower
(000139)
Table 5-1. General Troubleshooting Guide
Possible Cause
Low oil level
Oil leaking from engine
Oil pressure switch failure
Low coolant level
Blockage in radiator
Leakage in coolant hoses,
engine block, or water pump
Faulty thermostat
Water pump failure
Incorrect mix/frozen radiator
Low fuel level
Restricted air filter
PAS engaged
Verify oil level on dipstick. Add oil, if needed.
Inspect the engine for leaks.
Refer to OEM engine operator's manual to identify corrective
action.
Add coolant if needed. Allow engine to cool, then check coolant
level in radiator. Restart engine and check coolant temperature.
Stop engine immediately if coolant temperature is 210 °F (99 °C)
or more.
Inspect radiator shroud and ducting for blockage and remove any
foreign matter.
Inspect for visible leaks. Verify tension of water pump serpentine
drive belt.
Remove load on generator and restart engine. Verify coolant
temperature and shut engine down immediately if it starts to
overheat. Refer to the OEM engine operator's manual for
additional information on engine overheating.
Contact a GMP ASD to replace.
Contact a GMP ASD to replace.
Thaw the radiator with an external heat source and flush the
coolant system with the correct coolant mixture.
Check fuel level in tank.
Verify fuel pump operation.
Inspect air filter for blockage.
Refer to OEM engine operator's manual for additional
information.
Verify PAS is off.
Troubleshooting
Solution
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magnum mlt6skMlt6smMlt6sk3002908801