9 POS PLUG
PLUG LOCATION
PIN
LOWER
LOCATION
TO GND
BK/WT
POWER - DC
1
BAR
RD/BK
2
POWER + DC
RD/VI
FUEL
3
RD/YL
START
4
OR
5
CHARGE ALT
BK
BK
OUTPUT C
TO RELAY 1
6
BL
TO RELAY 2
OUTPUT D
7
SEE AC DIAGRAM
RD
TO RELAY 3
OUTPUT E
8
YL
TO RELAY 4
OUTPUT F
9
11 POS PLUG
PLUG LOCATION
PIN
LOWER
LOCATION
VI
GLOW
OUTPUT G
10
GY/GN
MAST UP
11
OUTPUT H
GY/BK
MAST DOWN
OUTPUT I
12
VI
SYSTEM IN AUTO MODE
OUTPUT J
13
BK/WT
14
ANALOG IN COM
WT/BL
OIL PRESSURE
ANALOG INPUT A
15
WT/YL
TEMPERATURE
16
ANALOG INPUT B
17
ANALOG INPUT C
18
CAN H
CAN L
19
CAN SCREEN
20
4 POS PLUG (GEN VOLTAGE)
PLUG LOCATION
PIN
UPPER
LOCATION
BK
PHASE L1 VOLTAGE
21
PHASE L2 VOLTAGE
SEE AC DIAGRAM
22
RD
PHASE L3 VOLTAGE
23
WT
NEUTRAL
24
TO GND
BAR
5 POS PLUG (GEN CURRENT)
PLUG LOCATION
PIN
UPPER
LOCATION
WT
BK
PHASE L1 CURRENT
25
CT-1
PHASE L2 CURRENT
26
WT
BK
TO GND
PHASE L3 CURRENT
27
CT-3
BAR
BK/WT
PHASE GND
29
TO GND
BAR
TO GND
BAR
348 OHM
RESISTOR
66234
BL
WT
BK/WT
SPLICE
6 POS PLUG (BINARY INPUTS)
TO GND
A
#7
B
PLUG LOCATION
BAR
PIN
LOWER
LOCATION
YL/GN
PHOTO SENSOR
INPUT A
30
INPUT B
31
INPUT C
32
INPUT D
33
BN
UP STOP
INPUT E
34
BK
DOWN STOP
INPUT F
35
SWITCH INPUTS TO GND
RD/BK
RD/WT
10A
1
RD/WT
1
RD/WT
2
2
RD/YL
3
3
YL
OR
4
4
OR
5
5
RD/VI
RD/VI
6
6
WT/BL
WT/BL
7
BK/YL
7
BK/YL
8
8
WT/YL
9
9
WT/YL
VI
VI
10
10
YL/GN
YL
11
11
BK/WT
BK/WT
12
12
TO GND
BAR
OPTIONAL ELECTRIC
WINCH
GY/GN
1
1
GY/BK
2
2
SEE
3
3
ELECTRIC
BN
WINCH
OPTION
BK
4
4
DIAGRAM
5
5
BK/WT
TO GND
BAR
ENG. GND
VI/YL
VI/YL
87
RD/VI
86
RD
85
BK/WT
FUSE
LINK
OVERHEAT
FUEL
WARNING
RELAY
SWITCH (N.O.)
OR
NIGHT WATCHMAN
PHOTO SENSOR
ALTERNATOR
FUSE
LINK
ALT B+
BL
START
RELAY
ALT B+
30 RD
85 BK/WT
87 RD/YL
87 RD/YL
87 RD/YL
86 YL
OPT.
HFF
VI/YL
VI/YL
SPLICE
A
#1
B
VI/YL
SPLICE
30
30
RD
A
#2
B
86
BK/YL
85
BK/WT
87
BL
CONTROL
ENG
VI/YL
BL
FUSE
BL
GND
LINK
OIL
GLOW
PRESSURE
PLUG
WARNING
SWITCH (N.C.)
ALT B+
GLOW
RELAY
FUEL
PUMP
RD
12V BATTERY
STARTER
RD
RD/YL
SPADE
SPADE
BK/WT
LIGHT
BK/WT
ENG. GND