Light Operation (Key Switch Models); Light Operation (Power Zone-Dla) (If Equipped); Engine Derating - Generac Power Systems MAGNUM MLT6SM Owner's Manual

Light tower
Table of Contents

Advertisement

Light Operation (Key Switch
Models)
WARNING
Burn hazard. Never operate lights with a
damaged or missing lens cover. Lamps are
hot and pressurized while in use. Unprotected
lamps can shatter, causing severe injury.
1. Verify the unit is ON and running smoothly.
2. See
Figure
3-11. Switch the main circuit breaker
(A) ON (I).
3. Switch the individual circuit breakers for the lights
(B) ON (I), one at a time.
A
Figure 3-11. Light Switches and Breaker
NOTE: The lights require a warm up period of 5–15
minutes before they reach full output. If the lights are shut
down, they require a cool down period of approximately
10 minutes before they can be switched on again.
NOTE: The light tower uses four 1000W, 1050W or
1100W bulbs. When checking or replacing the bulbs,
wipe them with a clean cloth to avoid leaving any grease,
oil residue or fingerprints on the glass. Any residue can
create a hot spot on the bulb, causing premature bulb
failure.
WARNING
Burn hazard. Lamps become extremely hot
while in use. Allow 10–15 minutes for cooling
before handling or lowering mast. Touching a
hot lens or fixture can cause severe burns.
Owner's Manual for MLT6SM/6SK Light Tower
Light Operation (Power Zone–
DLA) (If Equipped)
See
Figure
the Power Zone–DLA. To view the light screen, press the
↑ button three times from the Home screen.
NOTE: The lights can only be turned ON and OFF while
the unit is running in MANUAL mode. They operate
(000277)
automatically in AUTO mode.
1. Once the engine is up to temperature and running
smoothly, switch the main circuit breaker ON (I).
2. To turn the light(s) ON, press the Select () button.
To turn the light(s) OFF, press the Select ()
button.
B
003991
003991
Burn hazard. Lamps become extremely hot
while in use. Allow 10–15 minutes for cooling
before handling or lowering mast. Touching a
hot lens or fixture can cause severe burns.

Engine Derating

(000278)
All units are subject to derating for altitude and
temperature. Derating reduces the available power for
operating tools and accessories connected to the
receptacles. For every increase in 1,000 ft (305 m) of
elevation, engine performance for this unit typically drops
between 2–4%. Also, engine performance decreases
about 1% for every 10 °F (5.6 ºC) increase in ambient air
temperature over 72 ºF (22 ºC).
3-12. The lights are turned on and off using
Figure 3-12. Lights Screen
WARNING
Operation
002327
(000278)
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magnum mlt6skMlt6smMlt6sk3002908801

Table of Contents