40
  Configuring the Dual-Meter Connection

Configuring the Dual-Meter Connection

Configuring Dual-Meter Connection Using SetApp
In the sample configuration described below, a SolarEdge energy meter with Modbus
connection is configured as a production meter, and is set to address 1, while an inline
meter is configured as an export/import meter, and is set to address 2.
To configure the SolarEdge energy meter with Modbus connection using SetApp:
 1. Verify that the meter at address 1 is configured as a production meter. From the
SetApp main menu, select Communication è RS485-x è Meter 1
 2. Verify the value of the following parameters:
Meter Function è Inverter Production
Protocol è SolarEdge
Device ID è 1
 3. Select Meter 2 to configure the export/import meter in the following steps:
 4. Select Meter Function, and select Export+Import.
 5. Set the inline meter's Modbus ID to address 2.

Verifying Meter Connections

Verifying the Meter Connections using SetApp
To verify the connectivity of two meters using SetApp, refer to Verifying the Inline
Meter Connection using SetApp on page 33

Troubleshooting Dual-Meter Connections

Troubleshooting Dual-Meter Connections using SetApp
To troubleshoot the connectivity of two meters using SetApp, refer to Troubleshooting
the Meter using SetApp on page 36