12
  Meter Interfaces
LEDs
The inline meter utilizes the orange and blue LEDs in the front of the unit (see the figure
above) in order to indicate the meter's status:
Orange: energy measurements
Blue: Energy Net/RS485 communication status
Function
Energy
measurements
Communication
status
LED
Blinking rate of 1000 pulses per hour indicates 1
Orange
kWh of measured energy.
Blinking: Meter is searching for an Energy Net
network, or is not connected to RS485 bus.
Lit: Meter is in the reboot state, or has
successfully paired with the Energy Net
Blue
network, or was successfully connected to the
RS485 bus.
Fast blinking during configuration of the inline
meter.
Inline Energy Meter with SolarEdge Energy Net Communications
Indication