Error Causes And Troubleshooting; Error Messages Of The Status Leds - Bosch rexroth IndraControl XFE 01.1 Operating Manual

Extension modules profibus, rt-ethernet, sercos, can
Hide thumbs Also See for rexroth IndraControl XFE 01.1:
Table of Contents

Advertisement

IndraControl XFE 01.1
13

Error causes and troubleshooting

13.1

Error messages of the status LEDs

For operating and error displays, refer to
⮫ Chapter 12.3 "LEDs on the XD1 plug " on page
Table 17: Voltage power connector
LED
LED display Cause
PW
LED is off
ON
LED is off
U
LED is off
L
Table 18: RT-Ethernet (Profinet, Ethernet/IP)
LED
LED display Cause
S
LED is off
L
LED is off
SF
Red
R911345570, Edition 06
⮫ Chapter 12.2 " LEDs on extension modules" on page 25
26.
Internal voltage error:
Voltage transformer is defective
24 V supply voltage is not connected
24 V supply voltage is connected with reverse polarity
Internally programmed function block is not loaded
24 V voltage errors:
24 V supply voltage is not connected
24 V supply voltage is connected with reverse polarity
No data is sent
No connection present
Master and slave:
LED flashes (1 Hz, 3 s): The DCP signal service is triggered via
the bus and it is only available for the Profinet device.
Master:
LED flashes (2 Hz): System error: invalid configuration, moni-
toring error or internal error
LED on (together with BF "red on"): Invalid master license
Slave:
LED on: Watchdog timeout; channel, generic or extended diag-
nostics present; system error
Error messages of the status LEDs
Bosch Rexroth AG
27 / 36