13.1.1 Error Cases After Commissioning The Can Module - Bosch rexroth IndraControl XFE 01.1 Operating Manual

Extension modules profibus, rt-ethernet, sercos, can
Hide thumbs Also See for rexroth IndraControl XFE 01.1:
Table of Contents

Advertisement

28 / 36
Error messages of the status LEDs
LED
LED display Cause
BF
Red
During normal mode (without errors), the LEDs "SF" and "BF" can also be on, but at low
intensity. This does not signal an error state. Check, whether additional diagnostic information
in available in the diagnostic log.
Table 19: Profibus
LED
LED display Cause
Stat
LED is acycli-
cally on
BF
LED is perma-
nently on
LED flashes Slave diagnostics
Table 20: Sercos
LED
LED display Cause
S
LED is off
L
LED is off
Table 21: CAN
LED
LED display Cause
PW
LED is off
ERR
LED is red
RUN
LED is off

13.1.1 Error cases after commissioning the CAN module

The following errors can be displayed when commissioning the CAN module, also refer to
⮫ Chapter 11.1 "Commissioning notes " on page
Bosch Rexroth AG
Master:
LED flashes (2 Hz): Configuration error: Not all configured I/O
devices are connected
LED on (together with SF "red on"): Hardware problem, field
bus stack cannot be loaded or there is no valid master license.
LED on (together with SF "red on"): No link, double IP, Hidden
Loop
Slave:
LED flashes (2 Hz): No data exchange
LED on: No configuration or slow physical connection, no phys-
ical connection or double IP
Module not configured
No connection
No data is sent
No connection present
Voltage error of the CAN voltage
Bus error, refer to the CANopen standard "CIA 303 Part 3: Indicator
Specification"
Communication error, refer to the CANopen standard "CIA 303 Part
3: Indicator Specification"