13. Troubleshooting

Malfunction
Sensor-switched light
without power
Sensor-switched light will
not switch ON
Sensor-switched light will
not switch OFF
Sensor-switched light
switches ON
without any identifiable
movement
Sensor-switched light
does not switch ON
despite movement
Emergency light malfunction
Malfunction
Backlight does not
switch ON
Cause
■ Fuse has tripped,
not switched ON,
break in wiring
■ Short circuit in mains power
supply lead
■ Any mains switch OFF
■ Wrong twilight setting selected
■ Mains switch OFF
■ Fuse has tripped
■ Continued movement within the
detection zone
■ Sensor-switched light not mounted
for detecting movement reliably
■ Movement occurred, but not
identified by the observer
(movement behind wall,
movement of a small object
in immediate lamp vicinity etc.)
■ To minimise malfunctioning, rapid
movements are suppressed or
detection zone too small
■ Wrong twilight setting selected
Cause
■ Emergency light charging
rechargeable battery
Remedy
■ Activate, change fuse,
turn ON mains switch, check
wiring with voltage tester
■ Check connections
■ Switch on mains switch
■ Reset
■ Switch ON
■ Activate, change fuse,
check connection if necessary
■ Check detection zone
■ Securely mount enclosure
■ Check detection zone
■ Check detection zone
■ Reset
Remedy
■ Wait for up to 24 hour until the
battery is fully recharged