Troubleshooting - STEINEL detector Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14

14. Troubleshooting

Malfunction
IS 2180-2
without power
IS 2180-2 will not switch
ON
IS 2180-2 will not switch
OFF
IS 2180-2 keeps switching
ON / OFF
IS 2180-2 switches on
when it should not
Cause
Fuse faulty; not switched
ON
Short circuit
Mains switch OFF
Twilight control set to
nighttime mode during
daytime operation
Bulb faulty
Mains power switch OFF
Fuse faulty
Detection zone not
properly targeted
Continuous movement in
the detection zone
Light is in detection zone
and keeps switching on
as a result of tempera-
ture change
Set to continuous
operation by indoor
series switch
Light is in detection zone
Animals moving in
detection zone
Heat source (e.g.
extractor hood outlet) in
detection zone
Wind is moving trees and
bushes in the detection
zone
Cars in the street are
being detected
Sudden temperature
changes due to weather
(wind, rain, snow) or air
expelled from fans or
open windows
– 21 –
Remedy
Renew fuse, switch on
mains power switch,
check wiring with voltage
tester
Check connections
Switch on
Adjust setting
Change light bulb
Switch on
Renew fuse, check
connection if necessary
Re-adjust
Check detection zone
and re-adjust if
necessary or fit shrouds
Re-adjust zone or apply
shroud
Set series switch to
automatic mode
Adjust detection zone
or fit shrouds, increase
distance
Adjust detection zone or
fit shrouds
Adjust detection zone or
fit shrouds
Blank off sections using
shrouds
Blank off sections using
shrouds
Adjust detection zone
or change site of
installation
GB

Advertisement

Table of Contents
loading

Table of Contents