Test 27 Result: Pes Header Test - Nielsen ID3 User Manual

Tag validator application
Table of Contents

Advertisement

Corresponding Log Message
If Validator determines that the PTS field is missing from the Nielsen ID3 DATA tag PES
header, it logs this error message:
Example
The example below shows that Validator found no PTS fields were missing from any
DATA-tag PES headers. The test passed because Validator allows up to 16 missing PTS
fields.

Test 27 Result: PES Header Test

Format
Format
Number of Errors
0
Maximum Tolerated
Meaning
Each Nielsen metadata PES packet header must have a stream ID of 0xBD and it must
include a non-zero PES packet size, as specified in the document "Timed Metadata for
HTTP Live Streaming." See "Related Documents" on page 7.
Corresponding Log Message
If the PES packet stream ID is incorrectly set or if the PES packet size of a Nielsen ID3
PES packet is set to 0, one of the following error messages is logged:
Example
The example below shows Validator found no PES header errors. The test passed
because Validator allows up to five errors.
Release 1.8 Revision F
-67: Missing PTS in Nielsen PES header.
MPEG-2: Missing PES PTS Test:
<number of PES-header errors / 0 / maximum
tolerated>
Number of errors detected
Not used
Maximum number of errors tolerated before failure is declared
-3:
Warning: PES header not valid for ID3 Tag Metadata Packet
-3:
Warning: PES packet length is set to 0!
MPEG - 2 : PES Header Test:
Pass <0/0/16>
Pass <0/0/5>
40