Test 12 Result: INFO Tag Count

Format
Summary Report
Format
Count
Minimum Required
0
Periodic Report
Format
Number of Seconds
0
Maximum Interval
Meaning
Summary Report
The INFO-tag check reports the number of INFO tags that occurred during the entire
length of processed content, as compared to the minimum number of INFO tags that
must be seen for the test to pass.
Periodic Reports
The INFO-tag test reports the number of seconds since the last INFO tag was detected in
the stream. If Validator has seen no INFO tags within the first 300 seconds of content, the
INFO-tag test reports the number of seconds since the start of content.
INFO tags are expected to arrive at 5-minute intervals. If 310 seconds expire without an
INFO tag, the INFO-tag check fails for that period.
Examples
Summary Report
In the example below, Validator found nine INFO tags in the stream. The test passed
because Validator requires a minimum of seven INFO tags.
Release 1.8 Revision F
<count of INFO tags/ minimum required / 0>
Number of INFO tags found in the stream
Minimum number of INFO tags required
Not used
<number of seconds since last INFO tag / 0 /
maximum interval between tags>
Number of seconds since last INFO tag
Not used
Maximum allowable interval between INFO tags
ID3 Tag: INFO Tag Count:
Pass <9/7/0>