Contec CNT24-2GY User Manual page 38

Isolated 24-bit up/down counter module for usb
Table of Contents

Advertisement

Table 3.2. Optional power supply
Type
Model
AC adapter
POA200-20-2
(Bundled)
AC-DC power
POW-AD13GY
supply
AC-DC power
POW-AD22GY
supply
DC-DC
POW-DD10GY
power supply
2 Output
AC input
DC input
Figure 3.17.
CNT24-2(USB)GY
Input
Output
90 - 264VAC 5.0VDC ± 5%
2.0A(Max.)
85 - 132VAC 5.0VDC ± 5%
3.0A(Max.)
85 - 265VAC 5.0VDC ± 5%
2.0A(Max.)
10 - 30VDC
5.0VDC ± 5%
3.0A(Max.)
*1
When you use the module in a noisy environment or
are nervous about noise, connect the power plug
MC1,5/3-ST-3,5 to the ground.
Optional power supply
Physical dimension
(mm)
47.5(W) x 75(D) x 27.3(H)
(No protrusions)
52.4(W) x 64.7(D) x 94.0(H)
(No protrusions)
52.4(W) x 64.7(D) x 94.0(H)
(No protrusions)
25.2(W) x 64.7(D) x 94.0(H)
(No protrusions)
3. Setup
DIN rail
-
Corresponding
Corresponding
Corresponding
MC1,5/3-ST-3,5 *1
(Phoenix Contact)
31