TORQUE SETTINGS FOR SCREWS:
ALL SCREWS MUST BE TIGHTENED WITH A TORQUE DRIVER. All screws are Allen Head
screws. Please see below for screw locations, screw quantity and torque settings. The number listed
in the "#" column corresponds to the location on the fixture. See the fixture diagram and number on
the next page for SCREW LOCATION depictions.
#
Screw Locations
1
Heat Sink to Head Front Cover (x8)
2
Sealed Back Cover to Head Back Cover (x4)
3
Yoke Arm Cover to Yoke Frame (8 x Each Side = 16 Total)
4
Access Cover to Yoke Frame (x4)
5
2nd Access Cover to Yoke Frame (x8)
6
Power & Data Connector to Base Casting (x10)
7
Handle to Base Casting (2 x Each Side = 4 Total)
8
Base Bottom Cover to Base Casting (x12)
9
Quick Lock Plate to Base Bottom Cover (x16)
10 Fixture Feet to Base Bottom (x4)
TORQUE DRIVERS (Recommended):
UTICA TS-30 (Shown)
ALTERNATIVE DRIVERS:
Proto J6107A
Wiha 28887
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES! TO
CONFIRM THE IP65 INTEGRITY AFTER A LAMP REPLACEMENT, TEST THE FIXTURE USING
THE IP TESTER.
TORQUE SETTINGS & IP TESTER
Screw Torque Settings
7.5-10.0 In-Lb
7.5-10.0 In-Lb
7.5-10.0 In-Lb
7.5-10.0 In-Lb
7.5-10.0 In-Lb
6.0-8.5 In-Lb
Fasten by Air Screwdriver
7.5-10.0 In-Lb
7.5-10.0 In-Lb
6.0-8.5 In-Lb
11