Controller's Tool Signals - Toshiba TH180 Instruction Manual

Industrial robot
Hide thumbs Also See for TH180:
Table of Contents

Advertisement

4.2.1 Controller's Tool Signals

The controller is provided with tool signals (i.e., five (5) input signals for sensor, etc.,
four (4) control signals for solenoid valve, etc., DC 24V and DC 24 VGND signals),
which can be connected also from the controller side. (A cable between the controller
and cable is an option.) The relevant signals are described below.
a)
Input signal connector HAND (Type-N)
Pin
Signal name
1
D-IN0
2
D-IN1
3
D-IN2
4
D-IN3
5
D-IN4
6
D-IN5
7
D-IN6
8
D-IN7
19
P24G
20
Table 4.1 Input signals
Signal No.
Input signal 0
Input signal 1
Input signal 2
Input signal 3
Input signal 4
Input signal 5
Input signal 6
Input signal 7
0V
TRANSPORTATION AND INSTALLATION MANUAL
Input circuit and example of
201
TS3000
TS3100
202
203
204
205
206
207
208
– 74 –
connections
Customer's side
P24V
?
?
Contract or
transistor
D-IN
?
P24G
[Source type (plus common]
STE 85389

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th250aTh350aTs3000

Table of Contents