5-21. CCU Y/R-Y/B-Y Adjustment
5-22. Setting After Finishing Adjustment
4. Set the menu as follows and adjust the CCU B-Y
sample using the MENU SELECT knob/ switch.
Test Point
: TP5 (B-Y)(GND:E1)/DA-88 panel
Adjustment Point:
MENU
: System config
PAGE
: VTR/CCU (S5)
ITEM
: CCU B-Y SAMP
Specifications : C = 350 ±2 mV
(Oscilloscope)
File Store:
Execute the file store. Throw the MENU SELECT switch
to ENTER to execute.
MENU
: Triming File
PAGE
: Triming File (T1)
ITEM
: File Store
5-28
5-22. Settings After Finishing Adjustment
• DETAIL OFF button/MSU operation panel → ON (Goes out)
• GAMMA OFF button/MSU operation panel →
• KNEE OFF button/MSU operation panel → ON (Goes out)
• Execute the reference file store.
MENU
: Reference File
PAGE
: Reference File (R1)
ITEM
: File Store
(Throw the MENU SELECT switch to ENTER to execute.)
4
DA
Y
TP3
R-Y
TP4
B-Y
TP5
GND
E1
DA-88 BOARD (A SIDE)
ON (Goes out)
3
2
1
A
TP1
B
TP2
C
D
E
F
G
BVP-500
BVP-500P