Confirmation After Adjustment; Preparation For Confirmation; Menu Operation; Confirmation - Sony SSC-DC593 Service Manual

Color video camera
Hide thumbs Also See for SSC-DC593:
Table of Contents

Advertisement

3-4. Confirmation after Adjustment

3-4-1. Preparation for Confirmation

Before performing the confirmation after adjustment,
remove the commander and adjustment commander relay
tool from the camera, and restart the unit.

3-4-2. Menu Operation

1. Set the MENU LOCK switch on the rear panel to OFF.
2. Press the MENU/ENTER button on the side panel and
keep pressing until the menu is displayed.
[CAMERA MAIN MENU]
> SYNC
EXPOSURE
DAY/NIGHT
WHITE BALANCE
ACTIVITY DETECTION
ZONE MASKING
OTHERS
CAMERA TITLE
USER PRESET
EXIT
3. Move the cursor to the item you want to select using
the up and down (↑, ↓) buttons on the side panel.
4. Press the MENU/ENTER button.
The menu of the selected item is displayed.
(The example below shows the screen when
EXPOSURE is selected.)
[EXPOSURE]
> AGC
SHUTTER
BLC
VARIABLE GAMMA
VIDEO LEVEL
RET
EXIT
. To select the item, move the cursor (>) using the up and
down (↑, ↓) buttons and to change the setting, move the
cursor using the left and right (←, →) buttons.
. Move the cursor to RET and press the MENU/ENTER
button to return to the previous screen, .
. To return to the normal screen, move the cursor to EXIT
and press the MENU/ENTER button.
3-8

3-5. Confirmation

3-5-1. Confirmation of fsc Adjustment

1. Set the DIP switch on the rear panel to LL.
2. Input a sync signal to the VS IN connector.
3. Check that the measuring frequency is within
specification.
[A]
Subject:
Measuring point:
Measuring equipment: Frequency counter
Specification:

3-5-2. Confirmation of 57 MHz Adjustment

1. Set the DIP switch on the rear panel to INT.
2. Check that the measuring frequency is within
specification.
[A]
OFF
OFF
OFF
OFF
L--*--H
Subject:
Measuring point:
Measuring equipment: Frequency counter
Specification:
CN202
IC304
TP202
PR-269 board (Side A)
Not required
PR-269 board, TP202
14.318181 ± 0.000080 MHz
(SSC-DC593)
17.734472 ± 0.000080 MHz
(SSC-DC593P/598P)
CN202
IC202
CL201
PR-269 board (Side A)
Not required
PR-269 board, CL201
57.272720 ± 0.000800 MHz
(SSC-DC593)
56.750000 ± 0.000800 MHz
(SSC-DC593P/598P)