Sony BVP-500 Maintenance Manual page 78

Color video camera
Table of Contents

Advertisement

5-1. Preparation
5-1-5. Initial Settings
BVP-500/500P
n
When switching the following switches from a customer-
set position, it is recommended to record the setting state
of the customer in the table below.
After adjustment is complete, be sure to return the switches
to their customer-set position.
Board
Switch
Initial setting Customer-set position
AT-95
S1-1
ON
S1-2
OFF
S1-3
ON
S1-4
OFF
IF-538
S200
RET
S650
VBS
MD-103
S3
PROMPT
AU-211
SW1
C (CARBON)
SW2-1
OFF
SW2-2
OFF
SW2-3
OFF
SW2-4
OFF
SW2-5
ON
SW2-6
OFF
SW2-7
OFF
SW2-8
OFF
SW3-1
OFF
SW3-2
ON
SW4
OFF
SW5
PHANTOM
SW6
MIC1
AU-215
S200
0 (0 dBu)
DM-98
S1-1
OFF
S1-2
OFF
S1-3
OFF
S1-4
ON
When adjusting a camera incorporating the OHB-500WS/
WSP, be sure to set the setup menu as follows.
MENU : Operation
PAGE : Wide Screen (?4)
ITEM : 16:9/4:3 MODE→16:9
5-4
MSU-700 Operation Panel
• CAM POWER/Signal output select buttons
→ OFF (Stays out)
ALL button
→ ON (Stays lit)
CAM PW button
→ ON (Stays lit)
VF PW button
→ OFF (Stays out)
TEST 1 button
→ OFF (Stays out)
TEST 2 button
→ OFF (Stays out)
BARS button
→ ON (Stays lit)
CLOSE button
• CAM/CCU Function ON/OFF buttons
→ OFF (Stays lit)
KNEE OFF button
→ OFF (Stays lit)
DETAIL OFF button
LVL DEP OFF button → OFF (Stays lit)
→ OFF (Stays out)
AUTO KNEE button
SKIN DETAIL button → OFF (Stays out)
• Others
GAMMA OFF button → ON(Stays out)
MASTER GAIN button→ 0 (0 dB)
FILTER button (ND) → 1 (Stays lit)
→ B (Stays lit)
FILTER button (CC)
• Menu operation block (Touch panel)
→ON
PAINT button
∆ →(Page 2/3)→ White Clip → White Clip Off
Preset of Compensation Data
When a board was replaced or repaired, preset the compen-
sation data, proceeding as follows. If the data is preset
once, be sure to carry out all steps of 5-2 thruogh 5-22.
Because presetting clears all adjustment data of video and
detail system.
1. Execute the reference file clear.
Throw the MENU SELECT switch to ENTER to
execute.
MENU : Reference File
PAGE : Reference File (R1)
ITEM
: Clear File
2. Execute the scene file standard.
STANDARD button/MSU operation panel→ON
BVP-500
BVP-500P

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bvp-500pDigital 1000