3-1. Setup Menu
3-1-2. Paint Menu
Page
Ver.
Item
DETAIL2
CLEAR
SKIN DETAIL
SKIN DETAIL
LEVEL
PHASE
WIDTH
SATURATION
GATE
1.10
AUTO HUE
CLEAR
GAMMA
GAMMA, R/G/B/M –99 to 99 ([0])
COARSE
GAMMA
1.07
BLACK GAMMA
1.07
BLACK GAMMA
TEST
CLEAR
KNEE/W.CLIP
POINT
SLOPE
KNEE
AUTO KNEE
KNEE MAX
WHITE CLIP
WHITE CLIP
TEST
CLEAR
e)
This function is inhibited while TALLY lamps are lit or by the setting of the System Config menu.
A noise appears on the screen during operation.
3-8
Settings
Contents
Throw MENU SELECT
Sets all settings on the DETAIL2 page to 0.
switch to ENTER
(When you throw MENU SELECT switch to ENTER, the "CLEAR" indication
to execute
flashes. Throw MENU SELECT switch to ENTER again to execute; throw to
CANCEL to cancel.)
ON, [OFF]
Turns the skin detail function on and off.
–99 to 99 ([0])
Adjusts the level of the skin detail.
100° to 170°([120])
Adjusts the hue for the skin detail function.
0° to 90° ([60])
Adjusts the color width for the skin detail function.
–99 to 99 ([0])
Adjusts the color saturation of the skin detail function.
ON, [OFF]
Turns the area display of the skin detail function in the viewfinder screen.
Throw MENU SELECT
Sets the range of skin detail hue function automatically.
switch to ENTER
(Locate the desired skin color within the gate marker of VF and measure.)
to execute.
Throw MENU SELECT
Sets all settings on the SKIN DETAIL page to 0.
switch to ENTER
(When you throw MENU SELECT switch to ENTER, the "CLEAR" indication
to execute.
flashes. Throw MENU SELECT switch to ENTER again to execute; throw to
CANCEL to cancel.)
Adjusts the R, G, B and master gamma level.
0.40, [0.45], 0.50
Selects the gamma value in steps.
[ON], OFF
Turns the gamma value on and off.
–99 to 99 ([0])
Adjusts the black gamma (master).
ON, [OFF]
Turns the black gamma function on and off.
1, 2, [OFF]
Selects the test signal.
1
: Outputs the sawtooth waveform test signal
2
: Outputs 3-step waveform test signal
OFF : No test signal is output
Throw MENU SELECT
Resets all settings on the GAMMA page to the factry settings.
switch to ENTER
(When you throw MENU SELECT switch to ENTER, the "CLEAR" indication
to execute.
flashes. Throw MENU SELECT switch to ENTER again to execute; throw to
CANCEL to cancel.)
–99 to 99 ([0])
Adjusts the knee point level when the function is OFF.
–99 to 99 ([0])
Adjusts the knee slope level when the function is OFF.
[ON], OFF
Turns the knee function on and off.
ON, [OFF]
Turns the auto knee function on and off.
ON, [OFF]
Turns on and off the knee max function which changes the slope to
completely collapsed form.
–99 to 99 ([0])
Adjusts the white clip level.
[ON],OFF
Turn the white clip function on and off.
1, 2, [OFF]
Selects the test signal.
1
: Outputs the sawtooth waveform test signal
2
: Outputs 3-step waveform test signal
OFF : No test signal is output
Throw MENU SELECT
Sets all settings on the KNEE/W.CLIP page to 0.
switch to ENTER
(When you throw MENU SELECT switch to ENTER, the "CLEAR" indication
to execute.
flashes. Throw MENU SELECT switch to ENTER again to execute; throw to
CANCEL to cancel.)
e)
e)
BVP-500P
BVP-500