Caution! When resistance is felt DO
NOT USE FORCE to turn the spindle any
further as this is the maximum shower
temperature obtainable with the available
hot water storage temperature. FORCE
will DAMAGE the internal components.
6.
Turn the temperature spindle until the
maximum water temperature required
is obtained.
Warmer - Turn spindle anticlockwise
Cooler - Turn spindle clockwise
7.
Insert the temperature hub with the pip
on the temperature hub aligned with
the slot on the thermostatic cartridge.
Secure the temperature hub with the
retaining screw.
8.
Insert the outer flow control knob in
the maximum flow position.
9.
Insert the temperature indicator trim
and the inner temperature control
knob.
Caution! If resistance is felt when
turning the inner temperature control
knob, DO NOT USE FORCE to
turn the knob any further as this will
DAMAGE internal components.
10. Make sure the inner temperature
control knob can be fully turned in
both directions.
11. Check the maximum temperature
setting. If necessary repeat the
temperature adjustment until the
required temperature is achieved.
1079321-W2-G
temperature hub with the slot in the
Maximum Flow Position
Inner Temperature Control Knob
20
Temperature Spindle
Align the pip on the
thermostatic cartridge.
Temperature Indicator Trim