7. Walk Test Procedure (Test Mode)
• The sensor will rotate from left to right, and can tilt downwards.
Adjust the sensor to point in the required direction and angle down
to limit forward range as required.
7
• The adjustment knobs located beneath the PIR light controller are factory set
to "Walk Test Mode" . Double check they are set as follows;
Time ON setting – fully anti-clockwise
Dusk (Lux) level setting – fully clockwise
• Turn the power to the unit ON. The lamp will immediately illuminate as the unit
goes through its "warm-up" period. After approximately 1 minute the lamp will
extinguish. This indicates the unit is wired correctly and the unit is in Test Mode.
• Try to remain outside the detection area during the warm-up period.
• The unit will now operate during daytime as well as at night, illuminating the
lamp for approx. 3 seconds each time. This allows testing to be carried out to
establish whether the sensor is covering the required area.