9. Manual Override Mode

The light can be switched ON for longer time periods by use of the Manual
Override Mode. This can be activated at night by using the isolation switch.
• Switch the isolation switch once (OFF/ON) within 1.5 seconds.
• The unit will now illuminate continuously for approximately 6 hours
or until it is switched back into Auto Mode.
• To return to Auto Mode switch the isolation switch OFF and then
back ON again within 1.5 seconds.

10. Troubleshooting

Problem
• The lamp stays ON
at night.
9
• The PIR keeps
activating for no
reason at random.
• The PIR will not
operate at all.
Solution
Cover the PIR lens with a thick cloth. If the light
turns OFF, check the detection area for heat or a
reflective source. If the light stays ON, check the wiring
(See section 6. Connection Diagram).
Turn OFF at the isolation switch. Turn back ON again
after 30 seconds. Leave for approximately 15 minutes.
If the light activates, check for false activation from
heat, wind or a reflective source.
Check that the power is switched ON at the power
supply or isolation switch.
Turn OFF the power to the unit and check the wiring
connections. Check the lamp (if it's changeable). If the
lamp has failed, replace. Ensure the lamp is seated
correctly in the lamp-holder. Please note that the unit
will not detect through glass (e.g. in a glazed porch).