RTCU LX5 pro Technical Manual V1.00
Advanced Industrial M2M/IoT Gateway
Rechargeable Li-Ion Backup Battery
The RTCU contains an internal Li-Ion battery for operation even when the external power is
absent, making it possible to report power loss etc. Please note, that when external power is
removed, the device will be powered down by default. This setting can be changed as documented
in the RTCU IDE documentation.
The battery charging is entirely automated and handled internally by the RTCU device – leaving
no need for user interaction. Different kinds of functions (Battery low, Charger enable, charging
status, etc.) are available to the user application.
The charge current is relatively high, for a shorter charge time, as specified in the technical
specification. Make sure both the power supply and cables can handle the high current.
Whenever a power failure has occurred, the battery will be charged to establish the capacity, thus
making the battery ready for the next power failure.
By default, the battery cannot be charged above 45C or below 0C. The RTCU offers to charge
down to -10 ˚C using a specialized algorithm to protect the battery.
If the temperature is above 45C, the charging will not start and will be postponed, until it is below
this threshold.
The temperature has a strong influence on the battery capacity. At 0C the capacity has dropped to
60% of the initial capacity, and it falls dramatically at lower temperatures.
The battery cycle (numbers of charges and discharges) also influences the capacity. After 300 cycles
the capacity has dropped to approximately 80% of the initial capacity.
Warning
Misusing the RTCU device may cause the built-in battery security circuit to be damaged.
•
Do not place the RTCU device in high-temperature locations such as in direct sunlight or near
engines. Using the RTCU device in this environment may result in loss of battery performance and
a shortened life expectancy.
•
Do not expose the device to water, saltwater or allow the battery to get wet.
•
Avoid strong impacts and shocks.
Logic IO ApS.
Holmboes Allé 14
8700 Horsens
Denmark
Page 22 of 37
Ph: (+45) 7625 0210
Fax: (+45) 7625 0211
Email: support@logicio.com
www.logicio.com
Need help?
Do you have a question about the RTCU LX5 pro and is the answer not in the manual?