[Source:]Current[:Level][:Immediate][:Amplitude] - ITech IT6400 Series Programming Manual

Bipolar dc power supply / battery simulator
Hide thumbs Also See for IT6400 Series:
Table of Contents

Advertisement

Arguments
0-999.999
Unit
S(second)
Example
OUTP:DEL 0.5
Query syntax
OUTPut:DELay?
Returns
< NRf >

[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]

This command sets the current value. The current value setting must meet
current upper limit and voltage limit.
Model
IT6411
IT6411S
IT6431
IT6432
IT6433
IT6432S
Command syntax
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude] <NRf >
Arguments
<NRf >
Unit
A(Amps)
Example
CURR 1,CURR2 7
Current value setting range
0.002A ~ 5.05A
0.00005A ~ 0.1A
0.01A ~ 10.05A
0.002A ~ 5.05A
0.002A ~ 2.55A
10uA ~ 21mA
Copyright © Itech Electronic Co., Ltd.
Output command
62

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

It6411It6431It6432It6433It6411sIt6432s

Table of Contents